Compliance properties of conduits used in vascular reconstruction

Author:

Tai N R1,Salacinski H J1,Edwards A2,Hamilton G1,Seifalian A M1

Affiliation:

1. Vascular Haemodynamic Laboratory, University Department of Surgery, Royal Free and University College Medical School, University College London and Royal Free Hospital, London, UK

2. CardioTech International Ltd, Wrexham, UK

Abstract

Abstract Background Compliance mismatch between native artery and prosthetic graft used for infrainguinal bypass is implicated in the aetiology of graft failure. The aim was to quantify the elastic properties of a new compliant poly(carbonate)polyurethane (CPU) vascular graft, and to compare the compliance properties of grafts made from CPU, expanded polytetrafluoroethylene (ePTFE), Dacron and human saphenous vein with that of human muscular artery. Methods A pulsatile flow phantom was used to perfuse vessel and prosthetic graft segments at physiological pulse pressure and flow. Intraluminal pressure was measured using a Millar Mikro-tip catheter transducer and vessel wall motion was determined with duplex ultrasonography using an echo-locked wall-tracking system. Diametrical compliance and a stiffness index were then calculated for each type of conduit over mean pressures ranging from 30 to 100 mmHg by 10-mmHg increments. Results The compliance values of CPU and artery (mean over the pressure range) were similar (mean(s.d.) 8·1(0·4) and 8·0(5·9) per cent per mmHg × 10−2 respectively), although the elastic behaviour of artery was anisotropic unlike CPU, which was isotropic. Dacron and ePTFE grafts had lower compliance values (1·8(1·2) and 1·2(0·3) per cent per mmHg × 10−2 respectively, averaged over the pressure range). In both these cases, compliance and stiffness differed significantly from that of artery over a mean pressure range of 30–90 mmHg. Human saphenous vein exhibited anisotropic behaviour and, although compliant at low pressure (30 mmHg), was markedly incompliant at higher pressures. Conclusion Compliant polyurethane grafts offer a greater degree of compliance match than either ePTFE or Dacron.

Publisher

Oxford University Press (OUP)

Subject

Surgery

Cited by 212 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3