LOCALIZATION OF CEREBROSPINAL FLUID LEAKS BY GADOLINIUM-ENHANCED MAGNETIC RESONANCE CISTERNOGRAPHY

Author:

Aydin Kubilay1,Terzibasioglu Ege2,Sencer Serra1,Sencer Altay3,Suoglu Yusufhan4,Karasu Aykut3,Kiris Talat3,Turantan M. Inan3

Affiliation:

1. Department of Neuroradiology, Istanbul Medical School, Istanbul University, Istanbul, Turkey

2. Department of Radiology, Istanbul Medical School, Istanbul University, Istanbul, Turkey

3. Department of Neurosurgery, Istanbul Medical School, Istanbul University, Istanbul, Turkey

4. Department of Otolaryngology, Istanbul Medical School, Istanbul University, Istanbul, Turkey

Abstract

Abstract OBJECTIVE Intrathecal gadolinium (Gd)-enhanced magnetic resonance (MR) cisternography is a newly introduced imaging method. Two main objectives of this study were to investigate the sensitivity of Gd-enhanced MR cisternography for presurgical localization of cerebrospinal fluid (CSF) leaks in patients with CSF rhinorrhea and to study the potential long-term adverse effects of intrathecal Gd application. METHODS Fifty-one patients (19 women; mean age, 36.2 yr) with CSF rhinorrhea were included in the study. A total of 0.5 ml of Gd was injected into the lumbar subarachnoid space. T1-weighted MR cisternographic images were obtained to detect CSF leakage. The patient's neurological states and vital signs were recorded for the first 24 hours after the procedure. Neurological evaluations were repeated 1, 3, and 12 months after the procedure. The patients were followed for at least 3 years with annual neurological examinations. RESULTS Gd-enhanced MR cisternography demonstrated CSF leaks in 43 of the 51 patients. The sensitivity of Gd-enhanced MR cisternography for localization of CSF leaks was 84%. Forty-four patients underwent surgery to repair dural tears. Surgical findings confirmed the results of Gd-enhanced cisternography in 43 of the 44 patients who underwent surgery (98%). Eight patients with negative Gd-enhanced MR cisternography had no active rhinorrhea at the time of procedure, and seven of them did not need surgery. None of the patients developed an acute adverse reaction that could be attributed to the procedure. None of the patients developed any neurological symptoms or signs caused by intrathecal Gd injection during a mean follow-up period of 4.12 years. CONCLUSION Gd-enhanced MR cisternography is a sensitive and safe imaging method for detection of CSF leaks in patients with rhinorrhea.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

Reference29 articles.

Cited by 60 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3