Bare Platinum vs Matrix Detachable Coils for the Endovascular Treatment of Intracranial Aneurysms: A Multivariate Logistic Regression Analysis and Review of the Literature

Author:

Smith Michelle J1,Mascitelli Justin2,Santillan Alejandro1,Brennan Jennifer Sousa3,Tsiouris A John1,Riina Howard A1,Gobin Y Pierre1

Affiliation:

1. Division of Interventional Neuroradiology, Department of Neurological Surgery, New York Presbyterian Hospital, Weill Cornell Medical Center, New York, New York

2. Department of Neurosurgery, Mount Sinai Medical Center, New York, New York

3. Department of Epidemiology and Public Health, Yale University School of Medicine, New Haven, Connecticut

Abstract

Abstract BACKGROUND: Despite increasing acceptance of endovascular coiling for treating intracranial aneurysms, incomplete occlusion remains a limitation. Attempts to reduce recanalization have prompted creation of polyglycolic/polylactic acid-coated (Matrix) coils shown to improve neointima formation; however, previous publications demonstrate conflicting results regarding their efficacy. Few studies account for factors influencing recurrence, and only 4 studies include bare platinum (BP) coil control groups. OBJECTIVE: To compare initial and short- and mid-term occlusion as well as retreatment rates using Matrix compared with BP coils. METHODS: Retrospective review of patients undergoing coiling of cerebral aneurysms from 2001 to 2005 was performed. Analysis included a multivariate logistic regression model designed to detect a 35% absolute difference in initial occlusion between coil treatment groups with 80% power. RESULTS: Complete initial occlusion was achieved in 64% of BP (n = 45) and 63% of Matrix (n = 56) cases (P = 1.0). Follow-up occlusion rates in the short term and mid term were 52% and 60%, respectively, for BP cases and 42% and 67%, respectively, for Matrix cases (P = .24 and P = .38, respectively). After adjusting for size, morphology, volumetric packing density, location, rupture, and balloon remodeling, no difference in initial and subsequent occlusion or retreatment rates for BP coils versus Matrix coils was appreciated. CONCLUSION: After controlling for factors influencing recanalization, this investigation failed to show a significant difference between coil groups.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Clinical Neurology,Surgery

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献