ANALYSIS OF COMPLICATIONS IN PATIENTS TREATED WITH THE X-STOP INTERSPINOUS PROCESS DECOMPRESSION SYSTEM

Author:

Barbagallo Giuseppe M.V.1,Olindo Giuseppe1,Corbino Leonardo1,Albanese Vincenzo1

Affiliation:

1. Department of Neurosurgery, Azienda Ospedaliero–Universitaria Policlinico “G. Rodolico,” Catania, Italy

Abstract

ABSTRACT OBJECTIVE The X-Stop Interspinous Process Decompression System (St. Francis Medical Technologies, Concord, CA) is an interspinous device used with increasing frequency in the treatment of degenerative lumbar spine conditions. To date, limited data are available on complications observed in association with X-Stop procedures, and even less information exists on their underlying causes. The aim of this study was to analyze a series of complications occurring at a single institution and their potential causes and propose an anatomic scoring system that may help to classify patients and prevent complications. METHODS Sixty-nine patients were treated with the X-Stop. Forty-six single-level and 23 double-level operations (92 devices) were performed according to recommended indications. The mean follow-up duration was 23 months. RESULTS Eight complications were recorded: 4 device dislocations and 4 spinous process (SP) fractures, including 2 spontaneous fractures of the L4 SP in patients treated at L3–L4 and L4–L5. The following anatomic variants were demonstrated: markedly decreased interspinous distance (kissing spine–like), with concomitant facet joint hypertrophy, a posterior V-shaped interspinous area, limited accessibility of the space between the base and the tip of the SP because of facet joint hypertrophy and variations in the shape of the inferior surface of the cranial SP. CONCLUSION This is the first study focusing on interspinous distractor complications and the anatomic features of the SP and interspinous areas of the patients, which could potentially be the underlying causes for those complications. The X-Stop can be an effective treatment option, but it is not a panacea for all patients with degenerative lumbar spine conditions. Not only do the clinical indications deserve attention, but also, and most importantly, the patient's anatomic characteristics.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

Reference27 articles.

1. Treatment of neurogenic claudication by interspinous decompression: Application of the X STOP device in patients with lumbar degenerative spondylolisthesis;Anderson;J Neurosurg Spine,2006

2. Barbagallo G , OlindoG, CorbinoL, PlataniaN, AlbaneseV Analysis of results and complications associated with the X-Stop Interspinous device in a cohort of 37 patients with a 6 to 18 months follow-up. Presented at the 7th Annual SAS Global Symposium on Motion Preservation Technologies, Berlin, Germany, May 5–7, 2007.

3. Kissing spines: Fact or fancy?;Beks;Acta Neurochir (Wien),1989

4. Self-rated evaluation of outcome of the implantation of interspinous process distraction (X-Stop) for neurogenic claudication;Brussee;Eur Spine J,2008

5. Interspinous process decompression (IPD) system (X-STOP) for the treatment of lumbar spinal stenosis;Chiu;Surg Technol Int,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3