A Simple 3D Printed Model for Intracranial Vascular Anastomosis Practice and the Rochester Bypass Training Score

Author:

Rahmani Redi1,Santangelo Gabrielle1ORCID,Jalal Muhammad I.2,Catanzaro Michael3,Samodal Joshua1,Bender Matthew T.1,Stone Jonathan J.1

Affiliation:

1. Department of Neurosurgery, University of Rochester Medical Center, Rochester, New York, USA;

2. University of Rochester, School of Medicine and Dentistry, Rochester, New York, USA;

3. Department of Plastic Surgery, University of Rochester Medical Center, Rochester, New York, USA

Abstract

BACKGROUND AND OBJECTIVES: Surgical simulation models in cranial neurosurgery are needed to allow affordable, accessible, and validated practice in resident education. Current bypass anastomosis practice models revolve around basic tube tying or complex animal and 3-dimensional models. This study sought to design and validate a 3-dimensional printed model for intracranial anastomosis training. METHODS: A computer-aided design (CAD) generic skull was uploaded into Meshmixer (v.3.5), and a 55-mm opening was created on the right side, mimicking a standard orbitozygomatic craniotomy. The model was rotated 15° upward and 35° left, before a 10-mm square frame was added 80-mm deep to the right orbit. The CAD model was uploaded to GrabCAD and printed using a J750 PolyJet 3D printer before being paired with a vascular anastomosis kit. The model was validated with standardized assessments of residents and attendings by simulating an “M2 to P2” bypass. The Rochester Bypass Training Score (RBTS) was created to assess bypass patency, back wall suturing, and suture quality. Postsimulation survey data regarding the realism and usefulness of the simulation were collected. RESULTS: Five junior residents (Postgraduate Year 1-4), 3 senior residents (Postgraduate Year 5-7), and 2 attendings were participated. The mean operative time in minutes was as follows: junior residents 78, senior residents 33, and attendings 50. The RBTS means were as follows: junior residents 2.4, senior residents 4.0, and attendings 5.0. Participants agreed that the model was realistic, useful for improving operative technique, and would increase comfort in bypass procedures. There are a few different printing options, varying in model infill and printing material used. For this experiment, a mix of Vero plastics were used totaling $309.09 per model; however, using the more common printing material polylactic acid brings the cost to $17.27 for a comparable model. CONCLUSION: This study presents an affordable, realistic, and educational intracranial vascular anastomosis simulator and introduces the RBTS for assessment.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3