Abstract

BACKGROUND AND OBJECTIVES: The digital subtraction angiography is still the gold standard in the follow-up after aneurysm surgery, although it remains a repeating invasive technique with accumulating X-ray exposure. An alternative magnetic resonance angiography has the disadvantage of metal-related artifacts. A metal-free aneurysm clip could overcome this problem. Recent advances in manufacturing technologies of fiber-reinforced plastics might allow developing a prototype of a metal-free clip. METHODS: The prototype was formed out of carbon fiber–reinforced polyetheretherketone (CF-PEEK) in accordance with the standard clip design. In vivo and in vitro studies were performed to analyze the central nervous system biocompatibility. The prototype was tested in a phantom in a 3 T MRI scanner and microtomography scanner. For in vivo assessment, the left renal artery of rats was either ligated with a suture, clipped with a regular titanium clip or with the CF-PEEK prototype clip. The animals underwent standard MRI sequences and magnetic resonance angiography and assessment by a blinded neuroradiologist. RESULTS: Phantom studies showed no signs of artifacts. The prototype showed a reliable clamping and reopening after clip application, although the clamping force was reduced. In vivo studies showed a successful occlusion of the renal artery in all cases in the magnetic resonance angiography. Clip artifacts were statistically significant reduced in the prototype group (P < .01). CF-PEEK showed no signs of impaired biocompatibility compared with the titanium samples in vitro and in vivo. CONCLUSION: Former attempts of metal-free aneurysm clips did not meet the criteria of the standard clip design. In this study, the practicability of this new CF-PEEK artifact-free aneurysm clip has been proven. The further fabrication developments should overcome the problem of a reduced clamping force in the future. After clinical approval, it will improve the magnetic resonance image quality and might help to reduce the amount of digital subtraction angiography in the follow-up.

Funder

Bundesministerium für Bildung und Forschung

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3