Flow Diversion Effect in a Saphenous Vein Graft Aneurysm Using a Double-Layer Micromesh Stent: A Case Report

Author:

Dobashi Kazumasa1,Akamatsu Yosuke12ORCID,Yoshida Jun1,Chida Kohei1,Koji Takahiro1,Mori Futoshi3,Yoshida Kenji1,Kubo Yoshitaka1,Sasaki Makoto3,Ogasawara Kuniaki1

Affiliation:

1. Department of Neurosurgery, Iwate Medical University School of Medicine, Yahaba-cho, Iwate, Japan;

2. Department of Neurosurgery, Iwate Prefectural Chubu Hospital, Kitakami, Iwate, Japan;

3. Division of Ultrahigh Field MRI, Institute for Biomedical Sciences, Iwate Medical University, Yahaba, Iwate, Japan

Abstract

BACKGROUND AND IMPORTANCE: A double-layer micromesh stent is designed for the treatment of carotid artery stenosis that has been reported to potentially provide a flow diversion effect. However, the actual flow diversion effect of stents remains unclear. Here, we present a case of a growing saphenous vein graft (SVG) aneurysm treated with the placement of the double-layer micromesh stent using its flow diversion effect. CLINICAL PRESENTATION: A 66-year-old woman, who underwent high-flow bypass using a SVG for a blister-like internal carotid artery aneurysm 13 years earlier at our institute, was referred to our hospital with a pulsatile cervical mass. Magnetic resonance angiography showed a 9-mm aneurysm on the left SVG, although the aneurysm was a small pouch 4 years earlier. Digital subtracted angiography demonstrated a 9.4 × 8.3-mm aneurysm from the SVG at the auricular level. Because the diameter of the graft was larger than that of the available flow diverter stents in Japan, we decided to place the double-layer micromesh stent (CASPER RX, 7 × 25 mm MicroVention) using its flow diversion effect. Computational fluid dynamics analysis before and after stent deployment showed a significant reduction in the average flow velocity and wall shear stress in the aneurysm, indicating actual flow diversion. An angiogram 2 months postoperatively showed complete obliteration of the aneurysm. CONCLUSION: Obliteration of the saphenous vein aneurysm was achieved because of the flow diversion effect of the double-layer micromesh stent. The stents might be a feasible alternative for treating cervical carotid aneurysms.

Funder

Japan Society for the Promotion of Science

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference20 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3