Purpose. To develop a method of circular buckle length calculation for optimization of circular scleral buckling in retinal detachment surgery.Methods. At the first stage of the study a formula for calculation of optimal circular scleral buckle length for patients with various axial length (AL) of the eyeball was developed (90 eyes). These healthy eyes were divided into three groups, 30 eyes in each: group 1 — AL 19 to 23.5 mm, group 2 — AL 23.6 to 27 mm, group 3 — AL over 27 mm. In all the groups AL and equatorial diameter of the eyeball were measured with ultrasound A- and B- scanning (Тomey UD8000, Tomey AL 3000). Mathematic estimation of equatorial eyeball diameter dependence on AL was performed using correlation and regression analysis and the formula for optimal circular buckle length calculation was derived. At the second stage the derived formula was used in clinic during retinal detachment surgery in 15 eyes of 15 patients aged 28 to 44 years (37.6 ± 2.6) with subtotal retinal detachment occupying 2 to 3 quadrants. Follow-up period was 1 to 4 months (2.3 ± 0.5). For control, in all patient’s intraoperative measurement of the eyeball circumference in equatorial zone was performed.Results. The first step of the study revealed high correlation coefficient (r) between AL and equatorial eyeball diameter in groups 1 and 2, 0.89 and 0.87, respectively. In group 3 correlation coefficient was 0.57 which shows moderate correlation between AL and equatorial eyeball diameter. Group 3 (AL > 27 mm) was not included in deriving the formula for circular buckle length calculation. Finally, regression equation was obtained and the following formula for circular buckle length calculation was derived: L = 0.9π (8.05 + 0.66 AL), where L — circular buckle length, π = 3.14, AL — axial length of the eyeball. At the second stage of the study (eyes with AL less than 27 mm) anatomical attachment of the retina was achieved in all 15 cases (100 %), elevation of the buckle was 1.44 to 1.6 mm (1.5 ± 0.02), circular buckle shortening made 10 % of the initial eyeball diameter. Control measurement of eyeball diameter in equatorial zone coincided with calculated values, that is, equaled the data obtained from presented formula and from preoperative ultrasound measurement of equatorial eyeball diameter.Conclusions. The derived formula for circular buckle length calculation is highly effective for eyes with AL less than 27 mm: provides optimal height of impression roll (approximately 1.5 mm), reduces the risk of postoperative complications, it is simple in use and shortens the operation time. For calculation of circular buckle length for eyes with AL over 27 mm it is reasonable to use the data of preoperative ultrasound A-scan measurement of equatorial diameter of the eyeball.

Publisher

PE Polunina Elizareta Gennadievna

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3