Abstract
Wavelength measurements have been carried out on the radiation at 9.3 pm from a stabilized CO
2
laser. The wavelength in vacuum was determined as 9 317 246 348 femtometres (fm), with a standard error of the mean of 11 fm (1.14 parts in 10
9
) and a total systematic uncertainty of ± 13 fm ( ± 1.4 parts in 10
9
). An upconversion technique of optical mixing in a non-linear crystal was used, so that the interferometric wavelength measurement was carried out on visible difference-frequency radiation at 679 nm. Its wavelength was determined relative to that of an iodine-stabilized He-Ne laser at 633 nm, by using plane-parallel Fabry-Perot interferometers. When combined with the result of the frequency measurement described in part I, this wavelength measurement leads to a value for the speed of light in vacuum of 299792459.0 ± 0.6 m/s (Blaney et al. 1974). This result is in agreement (within the quoted uncertainties) with the value recommended internationally by the 14th General Conference of Weights and Measures in 1975.
Reference32 articles.
1. Bardsley W . Davies P. H. Hobden H. V. Hulme K. F. Jones O. Pomeroy W. & Warner J. 1969 Opto-electronics 1 29-31.
2. A ppl;Barger R. L.;Phys. Lett.,1973
3. Bayer-Helms F. & Engelhard E. 1962 Com. Consult. Definition Metre (Com. Int. Poids Mesures) 3rd Session 83-89.
4. Lasers, metrology and standards