Lumped parameter liver simulation to predict acute haemodynamic alterations following partial resections

Author:

Tithof Jeffrey1ORCID,Pruett Timothy L.2,Rao Joseph Sushil23

Affiliation:

1. Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE, Minneapolis, MN 55455, USA

2. Division of Solid Organ Transplantation, Department of Surgery, University of Minnesota, Minneapolis, MN, USA

3. Schulze Diabetes Institute, Department of Surgery, University of Minnesota, 420 Delaware Street SE, Minneapolis, MN 55455, USA

Abstract

Partial liver resections are routinely performed in living donor liver transplantation and to debulk tumours in liver malignancies, but surgical decisions on vessel reconstruction for adequate inflow and outflow are challenging. Pre-operative evaluation is often limited to radiological imaging, which fails to account for post-resection haemodynamic alterations. Substantial evidence suggests post-surgical increase in local volume flow rate enhances shear stress, signalling hepatic regeneration, but excessive shear stress has been postulated to result in small for size syndrome and liver failure. Predicting haemodynamic alterations throughout the liver is particularly challenging due to the dendritic architecture of the vasculature, spanning several orders of magnitude in diameter. Therefore, we developed a mathematical lumped parameter model with realistic heterogeneities capturing inflow/outflow of the human liver to simulate acute perfusion alterations following surgical resection. Our model is parametrized using clinical measurements, relies on a single free parameter and accurately captures established perfusion characteristics. We quantify acute changes in volume flow rate, flow speed and wall shear stress following variable, realistic liver resections and make comparisons with the intact liver. Our numerical model runs in minutes and can be adapted to patient-specific anatomy, providing a novel computational tool aimed at assisting pre- and intra-operative surgical decisions for liver resections.

Funder

Burroughs Wellcome Fund

Publisher

The Royal Society

Subject

Biomedical Engineering,Biochemistry,Biomaterials,Bioengineering,Biophysics,Biotechnology

Reference94 articles.

1. Lautt WW. 2009 Hepatic circulation: physiology and pathophysiology. In Colloquium series on integrated systems physiology: from molecule to function to disease (eds D Granger JP Granger). San Rafael CA: Morgan & Claypool Life Sciences. Copyright © 2010 by Morgan & Claypool Life Sciences.

2. The anatomy of the liver;Couinaud C;Ann. Ital. Chir.,1992

3. Kiernan on the anatomy and physiology of the liver;Kiernan F;Med. Chir. Rev.,1834

4. Three-dimensional reconstruction of parenchymal units in the liver of the rat

5. Regulation of hepatic microcirculation in stepwise liver resection;Dahmen U;Acta Gastroenterol. Belg.,2007

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3