Application of Multislice Spiral CT in Diagnosis of Ankle Joint Sports Injury

Author:

Hui Qiuli1

Affiliation:

1. Henan University of Chinese Medicine, Zhengzhou Henan, 450016, China

Abstract

In recent years, with the continuous improvement of medical treatment at home and abroad, computerized tomography (CT) technology has developed rapidly. The market competition at home and abroad is becoming increasingly fierce. The manufacturing cost of CT machines is highly valued by manufacturers. Reducing the manufacturing costs of CT machines is of great significance to medical equipment companies. The CT host is composed of a fixed control system and a rotation control system. Based on the analysis of the existing CT host system structure, this paper designs and implements a set of low-cost asynchronous variable-frequency rotation control systems based on the unchanged control interface of the existing main rotation servo control system, improving the market competitiveness of the product. Based on the constant structure of the rotating machine of the CT machine, the simulation analysis of asynchronous variable frequency control is carried out. A set of asynchronous variable frequency control design schemes and multi-stage speed curve control methods compatible with the original system structure are obtained. The verification and analysis of the functions of acceleration and deceleration control, rotation positioning, fault protection, electromagnetic radiation and other functions at the highest speed meet the system’s main performance requirements, such as acceleration and deceleration time at the highest speed, positioning accuracy, and speed stability. Through internal system verification, testing and clinical verification, the control system designed in this paper meets the design requirements. According to experimental data, the system is fully compatible with a running accuracy of 0.3%. The main performance indicators such as acceleration time and positioning accuracy have been improved. The acceleration time from static acceleration to the maximum speed of 0.39 seconds per revolution increases from 21 seconds to 19.9 seconds, and the positioning accuracy was improved from 0.3° to 0.24°. Finally, this study explores the diagnostic value of multislice spiral CT (MSCT) in ankle trauma.

Publisher

American Scientific Publishers

Subject

Health Informatics,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3