Registration Method Between Phase-Contrast Magnetic Resonance Angiography and Time-of-Flight Magnetic Resonance Angiography—A Preliminary Study

Author:

Nomura Seiji,Kin Taichi,Kunimatsu Akira,Shojima Masaaki,Watanebe Yasushi,Suzuki Yuuichi,Shono Naoyuki,Imai Hideaki,Saito Toki,Nakatomi Hirofumi,Oyama Hiroshi,Saito Nobuhito

Abstract

Purpose: To evaluate a new method that registers phase-contrast magnetic resonance angiography images to time-of-flight magnetic resonance angiography images. Methods: Magnetic resonance angiography datasets of 10 healthy volunteers obtained by using two modalities (phase-contrast magnetic resonance angiography and time-of-flight magnetic resonance angiography) were preprocessed. Specifically, vessel regions were extracted using the region growing method with a threshold of 10% of the signal intensity maximum or 50% of the signal intensity maximum for phase-contrast magnetic resonance angiography images and time-of-flight magnetic resonance angiography images, respectively. Then, the normalized mutual information method was used to determine spatial positions, and registration between non-preprocessed phase-contrast magnetic resonance angiography and time-of-flight magnetic resonance angiography was performed using the spatial position information. Misalignment of 3 anatomical points was used to compare the accuracy of registration in this data group (the proposed method group) to that in the data group without registration (the non-registration group) and that in the data group subjected to normalized mutual information-based registration without preprocessing (the non-preprocessing group). Results: The mean misalignment of 3 anatomical points ± standard error was 1.69 ± 0.11 mm in the proposed method group, and 2.77± 0.13 mm and 90.28 ± 8.24 mm in the non-registration group and non-preprocessing group, respectively. The mean misalignment of 3 anatomical points was significantly smaller in the proposed method group than in the non-registration group (p = 0 001). Conclusions: The proposed preprocessing and registration method improved the accuracy of normalized mutual information-based registration between phase-contrast magnetic resonance angiography images and time-of-flight magnetic resonance angiography images.

Publisher

American Scientific Publishers

Subject

Health Informatics,Radiology Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3