Abstract
The authors studied the availability of parenteral solutions of diazepam in glass bottles or polyethylene (PE) containers during infusion through polyvinyl chloride (PVC) administration sets. Diazepam solutions in concentration of 10O0mg/5OOml in 0.9% sodium chloride (NS) and 5% glucose (G5W) injection were infused at a flow rate of 30ml/h, and samples were taken from the bottle and at the end of the administration set, till 12 hours of infusion. The samples were tested in triplicate using ultraviolet spectrophotometry. The greatest loss of diazepam was observed in all solutions at 30 minutes of infusion (63.5% G5W glass, 60.5% NS glass, 55% G5W PE and 58% NS PE from the original concentration of 200 ug/ml). The diazepam concentrations in the containers did not significantly changed. The loss of diazepam from solutions infused through PVC administration sets should be kept in mind in severe clinical situations as status epilepticus, tetanus and eclampsia.
Subject
Neurology,Neurology (clinical)
Reference16 articles.
1. Estado de mal epiléptico;Arruda WO;Folha Médica,1987
2. Active management of severe pre-eclampsia;Baskett TF;Can Med Assoc J,1973
3. Trataiuento de Tétano Grave;Clausa RM,1981
4. Availability of diazepam from plastic containers;Cloyd JC;Am J Hosp Pharm,1980
5. The benzodiazepines: a review of their actions and uses relative to anaesthetic practice;Dundee JW;Br J Anaesth,1970