Histogram analysis in the differentiation between adrenal adenomas and pheochromocytomas: the value of a single measurement

Author:

Teixeira Ana P.1ORCID,Haddad Jr. William1ORCID,Barreto Luan Oliveira1ORCID,Secaf André2ORCID,Mermejo Livia M.1ORCID,Lucchesi Fabiano R.2ORCID,Tucci Jr. Silvio1ORCID,Elias Junior Jorge1ORCID,Molina Carlos A. F.1ORCID,Muglia Valdair F.1ORCID

Affiliation:

1. Universidade de São Paulo (FMRP-USP), Brazil

2. Hospital de Amor, Brazil

Abstract

Abstract Objective: To assess the diagnostic accuracy of histogram analysis on unenhanced computed tomography (CT) for differentiating between adrenal adenomas and pheochromocytomas (PCCs). Materials and Methods: We retrospectively identified patients with proven PCCs who had undergone CT examinations between January 2009 and July 2019 at one of two institutions. For each PCC, we selected one or two adenomas diagnosed within two weeks of the date of diagnosis of the PCC. For each lesion, two readers scored the size, determined the mean attenuation, and generated a voxel histogram. The 10th percentile (P10) was obtained from the conventional histogram analysis, as well as being calculated with the following formula: P10 = mean attenuation – (1.282 × standard deviation). The mean attenuation threshold, histogram analysis (observed) P10, and calculated P10 (calcP10) were compared in terms of their diagnostic accuracy. Results: We included 52 adenomas and 29 PCCs. The sensitivity, specificity, and accuracy of the mean attenuation threshold were 75.0%, 100.0%, and 82.5%, respectively, for reader 1, whereas they were 71.5%, 100.0%, and 81.5%, respectively, for reader 2. The sensitivity, specificity, and accuracy of the observed P10 and calcP10 were equal for both readers: 90.4%, 96.5%, and 92.6%, respectively, for reader 1; and 92.3%, 93.1%, and 92.6%, respectively, for reader 2. The increase in sensitivity was significant for both readers (p = 0.009 and p = 0.005, respectively). Conclusion: For differentiating between adenomas and PCCs, the histogram analysis (observed P10 and calcP10) appears to outperform the mean attenuation threshold as a diagnostic criterion.

Publisher

FapUNIFESP (SciELO)

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3