Analytical quality by design approach for the control of potentially counterfeit chloroquine with some NSAIDS using HPLC with fluorescence detection in pharmaceutical preparation and breast milk

Author:

Hassan Said A.1ORCID,Ibrahim Noha2,Elzanfaly Eman S.1,El Gendy Ahmed E.2

Affiliation:

1. 1Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt

2. 2Analytical Chemistry Department, Faculty of Pharmacy, Misr International University, Cairo, Egypt

Abstract

AbstractChloroquine phosphate (CQ) the antimalarial drug and suggested to treat the pandemic disease coronavirus (COVID-19) is often adulterated with some of the non-steroidal anti-inflammatory drugs (NSAIDs) such as paracetamol, aspirin (ASP), or both. The purpose of this study is to detect such counterfeited drugs, using a reversed phase high pressure liquid chromatography (RP-HPLC) method with fluorescence detection. Analysis was divided into three phases. In the first phase, a Plackett-Burman design (PBD) was used to screen five independent factors, namely, buffer pH, buffer concentration (mM), acetonitrile content (%), flow rate (mL/min) and triethylamine (TEA) content in the buffer preparation (%). The selected dependent variables were (resolution, symmetry of peaks and run time). The objective of the second phase was to optimize the method performance using Box-Behnken design (BBD) and desirability function for multiple response optimization to obtain the best chromatographic performance with the shortest run time. Optimal chromatographic separation was achieved on a YMC-pack pro C18 ODS-A column (15 cm × 4.6 mm, 5 µm) at room temperature The optimum mobile phase consisted of acetonitrile and 5 mM sodium dihydrogen phosphate buffer containing 0.5% triethyamine (30:70, v/v) with the pH adjusted to 3.5 using an orthophosphoric acid solution. The flow rate was maintained at 1 mL/min, and the detection was performed with a fluorescence detector fixed at 380 nm (λemission) after excitation at 335 nm (λexcitation). The third phase was method validation according to ICH guidelines, providing to be specific, precise, accurate, and robust. The method is linear over a range of 0.4–8 µg/mL for chloroquine and ASP, while for paracetamol it is linear over 16–48 µg/mL. The developed RP-HPLC method was used for quantitation of the three drugs in chloroquine dosage form samples. The method shows a great tendency in the classification between the genuine chloroquine and the adulterated ones in pharmaceutical preparations and breast milk.

Publisher

Akademiai Kiado Zrt.

Subject

General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3