Author:
Yang B.,Liu C.T.,Nieh T.G.,Morrison M.L.,Liaw P.K.,Buchanan R.A.
Abstract
In this study, we demonstrated that the failure of bulk metallic glasses (BMGs) results from a sudden temperature rise within a shear band. Using a shear transformation zone model, we successfully calculated the temperature within a shear band and found it consistent with the observation from an in situ infrared thermographic system. The instantaneous temperature within a shear band at fracture agrees remarkably well with the glass transition temperature (Tg providing a new criterion to determine the strength of BMGs from their Tg. This agreement also discloses the fact that catastrophic failure of BMG is caused by the sudden drop in viscosity inside the shear band when the instantaneous temperature within a shear band approaches Tg.
Publisher
Springer Science and Business Media LLC
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
105 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献