Comparison of Efficacy of a Novel Dual Channel Gastro Laryngeal Mask Airway versus Nasal Prongs for Airway Management in Day Care Gastrointestinal Endoscopy Procedures: A Randomised Clinical Study

Author:

Parmar Sejal,Kheskani Divya,Chhanwal Heena,Chaudhary Vipul

Abstract

Introduction: The Gastro Laryngeal Mask Airway (LMA) is a newer supraglottic airway device specifically designed for Gastroinstestinal (GI) endoscopy procedures. Hypoxia is a common complication in endoscopy procedures performed under sedation without securing the airway. The Gastro LMA allows for oxygenation, ventilation, and the passage of a gastroscope through its integrated endoscope channel. Aim: To evaluate the utility of the Gastro LMA compared to nasal prongs in maintaining oxygenation and airway control during upper GI endoscopy procedures. Materials and Methods: The present double-blinded randomised, single-centre clinical study conducted in the Department of Anaesthesiology, GCS Medical College Hospital and Research Centre, Ahmedabad, Gujarat, India included 50 adult patients scheduled for elective GI endoscopy procedures in the supine or lateral position. The patients were divided into two equal groups: Group G (Gastro LMA) and Group N (Nasal prong). Preprocedural heart rate and SpO2 levels were noted. All patients were observed for hypoxia (SpO2 <92%), bradycardia, lowest heart rate and Saturation of Peripheral Oxygen (SpO2 ) levels, conversion to endotracheal intubation, and any other intraoperative adverse events. Postoperatively, patients were observed for four hours for adverse effects and discharged after assessment using the modified Aldrete’s score. Statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 26.0, and the results were expressed as percentages, mean ± SD, and p-values. Results: Out of the 50 patients, 23 were male and 27 were female, with a median age of 59 years. The preprocedural mean lowest heart rate in Group G was 68/min, and in Group N it was 64/min. The mean lowest SpO2 during the procedure was 94% in Group N and 96% in Group G. In Group N, two patients (8%) required conversion to endotracheal intubation. One patient had a longer duration of the procedure and experienced bronchospasm, while another patient with Chronic Obstructive Pulmonary Disease (COPD) developed bronchospasm. In Group G, one patient (4%) required endotracheal intubation, possibly due to increased intrabdominal pressure caused by air insufflation in an obese patient. Conclusion: In patients undergoing gastrointestinal endoscopy procedures, the Gastro LMA appears to be effective for clinical use. It provides good airway control and enables deeper sedation without respiratory compromise. Ventilation was well maintained with minimal intraoperative and postoperative adverse events.

Publisher

JCDR Research and Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3