Diabetic Macular Edema Detection Using End-to-End Deep Fusion Model and Anatomical Landmark Visualization on an Edge Computing Device

Author:

Wang Ting-Yuan,Chen Yi-Hao,Chen Jiann-Torng,Liu Jung-Tzu,Wu Po-Yi,Chang Sung-Yen,Lee Ya-Wen,Su Kuo-Chen,Chen Ching-Long

Abstract

PurposeDiabetic macular edema (DME) is a common cause of vision impairment and blindness in patients with diabetes. However, vision loss can be prevented by regular eye examinations during primary care. This study aimed to design an artificial intelligence (AI) system to facilitate ophthalmology referrals by physicians.MethodsWe developed an end-to-end deep fusion model for DME classification and hard exudate (HE) detection. Based on the architecture of fusion model, we also applied a dual model which included an independent classifier and object detector to perform these two tasks separately. We used 35,001 annotated fundus images from three hospitals between 2007 and 2018 in Taiwan to create a private dataset. The Private dataset, Messidor-1 and Messidor-2 were used to assess the performance of the fusion model for DME classification and HE detection. A second object detector was trained to identify anatomical landmarks (optic disc and macula). We integrated the fusion model and the anatomical landmark detector, and evaluated their performance on an edge device, a device with limited compute resources.ResultsFor DME classification of our private testing dataset, Messidor-1 and Messidor-2, the area under the receiver operating characteristic curve (AUC) for the fusion model had values of 98.1, 95.2, and 95.8%, the sensitivities were 96.4, 88.7, and 87.4%, the specificities were 90.1, 90.2, and 90.2%, and the accuracies were 90.8, 90.0, and 89.9%, respectively. In addition, the AUC was not significantly different for the fusion and dual models for the three datasets (p = 0.743, 0.942, and 0.114, respectively). For HE detection, the fusion model achieved a sensitivity of 79.5%, a specificity of 87.7%, and an accuracy of 86.3% using our private testing dataset. The sensitivity of the fusion model was higher than that of the dual model (p = 0.048). For optic disc and macula detection, the second object detector achieved accuracies of 98.4% (optic disc) and 99.3% (macula). The fusion model and the anatomical landmark detector can be deployed on a portable edge device.ConclusionThis portable AI system exhibited excellent performance for the classification of DME, and the visualization of HE and anatomical locations. It facilitates interpretability and can serve as a clinical reference for physicians. Clinically, this system could be applied to diabetic eye screening to improve the interpretation of fundus imaging in patients with DME.

Funder

Industrial Technology Research Institute

Publisher

Frontiers Media SA

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3