The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test

Author:

Osmani Florent,Lago-Fuentes Carlos,Alemany-Iturriaga Josep,Barcala-Furelos Martín

Abstract

Introduction: The study aims to explore whether NIRS derived data can be used to identify the second ventilatory threshold (VT2) during a maximal incremental treadmill test in non-professional runners and to determine if there is a correlation between SmO2 and other valid and reliable exercise performance assessment measures or parameters for maximal incremental test, such as lactate concentration (LT), RPE, HR, and running power (W).Methods: 24 participants were recruited for the study (5 women and 19 men). The devices used consisted of the following: i) a muscle oxygen saturation analyzer placed on the vastus lateralis of the right leg, ii) the Stryd power meter for running, iii) the Polar H7 heart rate band; and iv) the lactate analyzer. In addition, a subjective perceived exertion scale (RPE 1-10) was used. All of the previously mentioned devices were used in a maximal incremental treadmill test, which began at a speed of 8 km/h with a 1% slope and a speed increase of 1.2 km/h every 3 min. This was followed by a 30-s break to collect the lactate data between each 3-min stage. Spearman correlation was carried out and the level of significance was set at p < 0.05.Results: The VT2 was observed at 87,41 ± 6,47% of the maximal aerobic speed (MAS) of each participant. No relationship between lactate data and SmO2 values (p = 0.076; r = −0.156) at the VT2 were found. No significant correlations were found between the SmO2 variables and the other variables (p > 0.05), but a high level of significance and strong correlations were found between all the following variables: power data (W), heart rate (HR), lactate concentration (LT) and RPE (p < 0.05; r > 0.5).Discussion: SmO2 data alone were not enough to determine the VT2, and there were no significant correlations between SmO2 and the other studied variables during the maximal incremental treadmill test. Only 8 subjects had a breakpoint at the VT2 determined by lactate data.Conclusion: The NIRS tool, Humon Hex, does not seem to be useful in determining VT2 and it does not correlate with the other variables in a maximal incremental treadmill test.

Publisher

Frontiers Media SA

Subject

Physiology (medical),Physiology

Reference41 articles.

1. Relationship between perceived exertion and blood lactate concentrations during incremental running test in young females;Abe;BMC Sports Sci. Med. Rehabil.,2015

2. Los límites del entrenamiento con control de frecuencia cardíaca y que información crucial proporciona el control de los niveles de oxígeno en los músculos. Humon AndersonP. 2017

3. Reliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise;Austin;Res. Q. Exerc Sport,2005

4. Understanding near infrared spectroscopy and its application to skeletal muscle research;Barstow;J. Appl,1985

5. Methodological aspects of maximal lactate steady state-implications for performance testing;Beneke;Eur. J. Appl. Physiol.,2003

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3