Prolonged Right Ventricular Outflow Tract Endocardial Activation Duration and Presence of Deceleration Zones in Patients With Idiopathic Premature Ventricular Contractions. Association With Low Voltage Areas

Author:

Parreira Leonor,Carmo Pedro,Marinheiro Rita,Mesquita Dinis,Farinha José,Esteves Ana,Amador Pedro,Ferreira António,Fonseca Marta,Caria Rui,Adragao Pedro

Abstract

Background and AimsThe wavefront propagation velocity in the myocardium with fibrosis is characterized by the presence of deceleration zones and late activated zones, that are absent in the normal myocardium. Our aim was to study the right ventricular outflow tract (RVOT) endocardial activation duration in sinus rhythm, and assess the presence of deceleration zones, in patients with premature ventricular contractions (PVCs) and in controls.MethodsWe studied 29 patients with idiopathic PVCs from the outflow tract, subjected to catheter ablation that had an activation and voltage map of the RVOT in sinus rhythm. A control group of 15 patients without PVCs that underwent ablation of supraventricular arrhythmias was also studied. RVOT endocardial activation duration and number of 10 ms isochrones across the RVOT were assessed. Propagation speed was calculated at the zone with the higher number of isochrones per cm radius. Deceleration zones were defined as zones with >3 isochrones within 1 cm radius. Low voltage areas were defined as areas with local electrogram with amplitude <1.5 mV.ResultsThe two groups did not differ in relation to age, gender or number of points in the map. RVOT endocardial activation duration and number of 10 ms isochrones were higher in the PVC group; 56 (41–66) ms vs. 39 (35–41) ms, p = 0.001 and 5 (4–8) vs. 4 (4–5), p = 0.001. Presence of deceleration zones and low voltage areas were more frequent in the PVC group; 20 (69%) vs. 0 (0%), p < 0.0001 and 21 (72%) vs. 0 (0%), p < 0.0001. The wavefront propagation speed was significantly lower in patients with PVCs than in the control group, 0.35 (0.27–0.40) vs. 0.63 (0.56–0.66) m/s, p < 0.0001. Patients with low voltage areas had longer activation duration 60 (52–67) vs. 36 (32–40) ms, p < 0.0001, more deceleration zones, 20 (95%) vs. 0 (0%), p < 0.0001, and lower wavefront propagation speed, 0.30 (0.26–0.36) vs. 0.54 (0.36–0.66) m/s, p = 0.002, than patients without low voltage areas.ConclusionRight ventricular outflow tract endocardial activation duration was longer, propagation speed was lower and deceleration zones were more frequent in patients with PVCs than in controls and were associated with the presence of low voltage areas.

Publisher

Frontiers Media SA

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3