The safety, efficacy, and functional outcomes on arthroscopic fixation of posterior cruciate ligament avulsion fracture by a bio-absorbable anchor or traditional pull-out technique: A prospective cohort study

Author:

Ren Xiangyu,Wang Jianing,Yang Shulong,Liu Zhe,Wang Tianda,Zhang Teng,Li Haoxin,Zhang Zhong

Abstract

Background: The posterior cruciate ligament avulsion fracture (PCLAF) is a special type of PCL rupture, and arthroscopic fixation for PCLAF has been recommended currently. The bio-absorbable suture anchor is a novel internal fixation for PCLAF. This study aims to estimate and compare the safety, efficacy, and functional outcomes between the bio-absorbable anchor and the traditional suture pull-out technique for arthroscopic fixation of PCLAF.Methods: This was a prospective cohort study. PCLAF patients were included from 1 January 2020, to 31 August 2021, in our department, and randomly divided into the absorbable anchor group and control group (pull-out suture fixation). Clinical assessments included: post drawer test, gravity test, anterior-posterior laxity (KT-2000), range of motion, Lysholm and International Knee Documentation Committee (IKDC) scores, total failure rate, and returning to sports rate. The minimum follow-up was 1 year (y).Results: 31 patients had accomplished the 1 year follow-up (missing rate: 13.9%). We did not face any complications such as neurovascular injury, fever, infection, un-union, or re-rupture during the follow-up. CT scan showed that all of the patients in the two groups had a well bone union at 3 months in post-operation. At 1 year follow-up, the total failure rate of the bio-absorbable anchor group (1/17, p = 0.036) was lower than the control group (5/14), and the IKDC (86.24 ± 4.35, p = 0.008) and return to sports rate (11/17, p = 0.045) of the bio-absorbable anchor group were higher than that of the control group (81.43 ± 5.06) (4/14).Conclusion: Both the bio-absorbable anchor and suture pull-out technique for arthroscopic fixation of PCLAF have acquired a well bone union and superior safety, but the bio-absorbable anchor group had better efficacy and functional outcomes than the traditional pull-out technique.

Publisher

Frontiers Media SA

Subject

Biomedical Engineering,Histology,Bioengineering,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3