Evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT between 2007 and 2021

Author:

Skawran Stephan12,Sartoretti Thomas12,Gennari Antonio G12,Schwyzer Moritz12,Sartoretti Elisabeth12,Treyer Valerie12,Maurer Alexander12,Huellner Martin W12,Waelti Stephan123,Messerli Michael12

Affiliation:

1. Department of Nuclear Medicine, University Hospital Zurich , Zurich, Switzerland

2. University of Zurich , Zurich, Switzerland

3. Department of Radiology and Nuclear Medicine, Children's Hospital of Eastern Switzerland , St. Gallen, Switzerland

Abstract

Objectives: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. Methods and materials: Data from all pediatric patients aged 0–18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. Results: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10–15) years; BMI: median 17.5 (IQR 15–20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman’s rho coefficients −0.46 and −0.35, respectively). Specifically, from 2007 to 2009 to 2019–2021 CTDIvol and DLP decreased from 2.94 (2.14–2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568–1.11) mGy and 108 (65.6–207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. Conclusion: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. Advances in knowledge: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Reference36 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3