The geometric and dosimetric accuracy of kilovoltage cone beam computed tomography images for adaptive treatment: a systematic review

Author:

Jassim Hussam123,Nedaei Hassan A.12,Geraily Ghazale12,Banaee Nooshin4,Kazemian Ali12

Affiliation:

1. Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran

2. Radiation Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran

3. Radiotherapy Department, National Cancer Hospital, Kufa, Iraq

4. Medical Radiation Research Center, Islamic Azad University, Tehran, Iran

Abstract

Objectives: To provide an overview and meta-analysis of different techniques adopted to accomplish kVCBCT for dose calculation and automated segmentation. Methods: A systematic review and meta-analysis were performed on eligible studies demonstrating kVCBCT-based dose calculation and automated contouring of different tumor features. Meta-analysis of the performance was accomplished on the reported γ analysis and dice similarity coefficient (DSC) score of both collected results as three subgroups (head and neck, chest, and abdomen). Results: After the literature scrutinization (n = 1008), 52 papers were recognized for the systematic review. Nine studies of dosimtric studies and eleven studies of geometric analysis were suitable for inclusion in meta-analysis. Using kVCBCT for treatment replanning depends on a method used. Deformable Image Registration (DIR) methods yielded small dosimetric error (≤2%), γ pass rate (≥90%) and DSC (≥0.8). Hounsfield Unit (HU) override and calibration curve-based methods also achieved satisfactory yielded small dosimetric error (≤2%) and γ pass rate ((≥90%), but they are prone to error due to their sensitivity to a vendor-specific variation in kVCBCT image quality. Conclusions: Large cohorts of patients ought to be undertaken to validate methods achieving low levels of dosimetric and geometric errors. Quality guidelines should be established when reporting on kVCBCT, which include agreed metrics for reporting on the quality of corrected kVCBCT and defines protocols of new site-specific standardized imaging used when obtaining kVCBCT images for adaptive radiotherapy. Advances in knowledge: This review gives useful knowledge about methods making kVCBCT feasible for kVCBCT-based adaptive radiotherapy, simplifying patient pathway and reducing concomitant imaging dose to the patient.

Publisher

Oxford University Press (OUP)

Subject

General Medicine

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3