Radiation dose and factors related to exceeding the diagnostic reference level in 496 transnasal ileus tube placement procedures from the REX-GI study

Author:

Nagaike Koji1,Hayashi Shiro23,Yakushijin Takayuki4,Yamamoto Masashi3,Sumiyoshi Tetsuya5,Yamaguchi Shinjiro6,Tamaru Yuzuru7,Yamada Takuya8,Tsumura Hidetaka9,Nakai Yousuke10,Doyama Hisashi11,Maetani Iruru12,Takagi Tadayuki13,Asai Satoshi14,Matsubara Kosuke15,Takenaka Mamoru16,Hosono Makoto17,Nishida Tsutomu3ORCID

Affiliation:

1. Department of Gastroenterology and Hepatology, Suita Municipal Hospital, Suita, Osaka, Japan

2. Department of Gastroenterology and Internal Medicine, Hayashi Clinic, Suita, Osaka, Japan

3. Department of Gastroenterology, Toyonaka Municipal Hospital, Toyonaka, Osaka, Japan

4. Department of Gastroenterology and Hepatology, Osaka General Medical Center, Osaka, Osaka, Japan

5. Department of Gastroenterology, Tonan Hospital, Sapporo, Hokkaido, Japan

6. Department of Gastroenterology and Hepatology, Kansai Rosai Hospital, Amagasaki, Hyogo, Japan

7. Department of Gastroenterology, National Hospital Organization Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan

8. Department of Gastroenterology and Hepatology, Osaka Rosai Hospital, Sakai, Osaka, Japan

9. Department of Gastroenterological Oncology, Hyogo Cancer Center, Akashi, Hyogo, Japan

10. Department of Gastroenterology, Graduate school of Medicine, The University of Tokyo, Tokyo, Japan

11. Department of Gastroenterology, Ishikawa Prefectural Central Hospital, Kanazawa, Ishikawa, Japan

12. Division of Gastroenterology and Hepatology, Department of Internal Medicine, Toho University Ohashi Medical Center, Tokyo, Japan

13. Department of Gastroenterology, Fukushima Medical University School of Medicine, Fukushima, Fukushima, Japan

14. Department of Gastroenterology, Tane General Hospital, Osaka, Osaka, Japan

15. Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan

16. Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Sayama, Osaka, Japan

17. Department of Radiology, Kindai University Faculty of Medicine, Sayama, Osaka, Japan

Abstract

Objective: We aimed to examine the factors contributing to radiation exposure exceeding the DRL of the transnasal ileus tube placement in this post hoc analysis from the cohort of the REX-GI study. Methods: Patients with transnasal ileus tubes were enrolled in the rex-gi study from may 2019 to december 2020. We investigated the endoscope insertion time (min), procedure time (min), tube insertion length (cm), fluoroscopy time (FT: min), air kerma at the patient entrance reference point (Ka.r: mGy), and air kerma–area product (PKA: Gycm2). The third quartile value of the PKA value was calculated as the diagnostic reference level (DRL) value. We explored the factors associated with radiation exposure exceeding the DRL. Results: In the REX-GI study, 496 patients who underwent transnasal ileus tube placement were enrolled. The median age of the patients was 71 years. The median endoscopy insertion time, procedure time, and tube insertion length were 6 min, 20 min, and 170 cm, respectively. The third quartile/median FT, Ka.r, and PKA were 18/11.9 min, 99.2/54.4 mGy, and 46.9/28 Gycm2, respectively. The third quartile value of PKA (47 Gycm2) was set as the DRL value. There were differences in distribution by the hospital. Compared with procedures under the DRL, the FT (19 vs 10 min), procedure time (25 vs 18 min), and tube insertion length (185 vs 165 cm) were significantly longer for procedures above the DRL. Conclusion: We report the DRL for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance. Advances in knowledge: Transnasal ileus tube placement under fluoroscopy guidance is a standard clinical procedure for bowel obstruction. However, the appropriate radiation dose level has not yet been established. We report the (DRL) for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3