Retrospective study of patients radiation dose during cardiac catheterization procedures

Author:

Osei Beverley12,Xu Lu23,Johnston Amanda4,Darko Sara5,Darko Johnson267,Osei Ernest2678

Affiliation:

1. Department of Health Sciences, McMaster University, Hamilton, ON, Canada

2. Department of Medical Physics, Grand River Regional Cancer Centre, Kitchener, ON, Canada

3. Department of Medical Sciences (IMS and Medical Biophysics), Western University, London, ON, Canada

4. St Mary General Hospital, Kitchener, ON, Canada

5. Department of Clinical Trials, Grand River Regional Cancer Centre, Kitchener, ON, Canada

6. Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada

7. Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada

8. Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada

Abstract

Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient’s clinical radiation dose data [kerma–area–product (KAP) and air-kerma at the interventional reference point (Ka,r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number of cine images) along with demographic information (age, height and weight) were collected from the hospital’s RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0–97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9–61.7) kg/m2 . The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1–203.2), 80.2 (18.9–208.5), 83.7 (48.0–246.1), 113.8 (60.9–284.5), 91.7 (6.0–426.0) and 51.1 (7.0–175.9) Gy-cm2 . The median Ka,r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3–3794.0), 1384.7 (291.7–4021.8), 1607.0 (883.5–4448.3), 2260.2 (867.4–5311.9), 1589.3 (100.2–7237.4) and 463.8 (67.7–1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients’ radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.

Publisher

British Institute of Radiology

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3