Affiliation:
1. Department of Orthopedic Surgery, Korea University Ansan Hospital, Ansan-si 15355, Republic of Korea
2. Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea
3. Department of Orthopedic Surgery, Chung-Ang University Hospital, College of Medicine, Chung-Ang University, Seoul 06974, Republic of Korea
Abstract
A CaO-SiO2-P2O5-B2O3 bioactive glass-ceramic (BGS-7) spacer provides high mechanical stability, produces a chemical bond to the adjacent endplate, and facilitates fusion after spine surgery. This prospective, randomized, single-blind, non-inferiority trial aimed to evaluate the radiographic outcomes and clinical efficacy of anterior cervical discectomy and fusion (ACDF) using a BGS-7 spacer for treating cervical degenerative disorders. Thirty-six patients underwent ACDF using a BGS-7 spacer (Group N), and 40 patients underwent ACDF using polyetheretherketone (PEEK) cages filled with a mixture of hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) for the treatment of cervical degenerative disorders. The spinal fusion rate was assessed 12 months postoperatively using three-dimensional computed tomography (CT) and dynamic radiographs. Clinical outcomes included patient-reported outcome measures, visual analog scale scores for neck and arm pain, and scores from the neck disability index (NDI), European Quality of Life-5 Dimensions (EQ-5D), and 12-item Short Form Survey (SF-12v2). All participants were randomly assigned to undergo ACDF using either a BGS-7 spacer or PEEK cage filled with HA and β-TCP. The primary outcome was the fusion rate on CT scan image at 12 months after ACDF surgery based on a per-protocol strategy. Clinical outcomes and adverse events were also assessed. The 12-month fusion rates for the BGS-7 and PEEK groups based on CT scans were 81.8% and 74.4%, respectively, while those based on dynamic radiographs were 78.1% and 73.7%, respectively, with no significant difference between the groups. There were no significant differences in the clinical outcomes between the two groups. Neck pain, arm pain, NDI, EQ-5D, and SF-12v2 scores significantly improved postoperatively, with no significant differences between the groups. No adverse events were observed in either group. In ACDF surgery, the BGS-7 spacer showed similar fusion rates and clinical outcomes as PEEK cages filled with HA and β-TCP.
Funder
BioAlpha Incorporation in Republic of Korea
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献