Development and Evaluation of Doppler Ultrasound Training Phantom for Human Vessel Simulation

Author:

Kim Nagyum12,Hong Cheolpyo1,Lee Changwoo2,Cho Hyo-Min2

Affiliation:

1. Department of Radiological Science, Daegu Catholic University, Gyeongsan-si 38430, Gyeongbuk, Republic of Korea

2. Medical Metrology Team, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Chungcheong, Republic of Korea

Abstract

The purpose of this study was to create a Doppler ultrasound training phantom aimed at aiding beginners in comprehending and effectively utilizing critical parameters during the learning process. Our designed training phantom does not require the use of a water pump or an automated injector. The fabrication of the vessel-mimicking phantom was accomplished using agarose gel. We utilized LEGO blocks to introduce a height difference that simulated blood flow within the phantom. The imitation blood material was prepared using glycerin. Ultrasound images were obtained using an Accuvix V10 device. This study utilized a Doppler ultrasound training phantom to facilitate stable imaging for beginners during scanning, due to its secure fixation. Furthermore, the fabricated vessel-mimicking phantom offers the advantage of adjusting the diameter of vessels during the fabrication process. Additionally, the easy adaptability, to tailor the phantom specifically for certain conditions by modifying only the vascular components, is another notable advantage. The experimental values for parameters such as the color box, scale, and color gain were collected. The spectral Doppler was used for a rough assessment of blood flow velocity. Color Doppler images, acquired via adjusting the color box to the left and right, displayed blood flow information in blue on the left, and red on the right. At a scale setting of 4 kHz and 0.6 kHz for color Doppler imaging, aliasing was absent at 4 kHz, but appeared at 0.6 kHz. Experiments involving various gain settings (2 dB, 5 dB, 10 dB, 35 dB, 60 dB, and 100 dB) demonstrated that the blood flow information was diminished at 2 dB, and exaggerated at 100 dB.

Funder

Korea Medical Device Development Fund

Korea Research Institute of Standards and Science

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference48 articles.

1. Quantification of tumor vascularity and flow with amplitude color Doppler sonography in an experimental model: Preliminary results;Meyerowitz;J. Ultrasound Med.,1996

2. Color Doppler energy: Computer analysis of color to assess angle dependency and detection of volume flow differences;Nilsson;J. Ultrasound Med.,1997

3. Value of duplex scanning in evaluation of crural and foot arteries in limbs with severe lower limb ischaemia—A prospective comparison with angiography;Karacagil;Eur. J. Vasc. Endovasc. Surg.,1996

4. Transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries: Examination technique and normal values in Korean;Kwun;J. Korean Neurosurg. Soc.,1989

5. General principles of carotid Doppler ultrasonography;Lee;Ultrasonography,2014