Clinical Outcomes of Second- versus First-Generation Carotid Stents: A Systematic Review and Meta-Analysis

Author:

Mazurek AdamORCID,Malinowski Krzysztof,Rosenfield Kenneth,Capoccia Laura,Speziale Francesco,de Donato GianmarcoORCID,Setacci Carlo,Wissgott Christian,Sirignano PasqualinoORCID,Tekieli Lukasz,Karpenko AndreyORCID,Kuczmik Waclaw,Stabile Eugenio,Metzger David Christopher,Amor Max,Siddiqui Adnan H.,Micari Antonio,Pieniążek Piotr,Cremonesi Alberto,Schofer Joachim,Schmidt Andrej,Musialek Piotr

Abstract

Background: Single-cohort studies suggest that second-generation stents (SGS; “mesh stents”) may improve carotid artery stenting (CAS) outcomes by limiting peri- and postprocedural cerebral embolism. SGS differ in the stent frame construction, mesh material, and design, as well as in mesh-to-frame position (inside/outside). Objectives: To compare clinical outcomes of SGS in relation to first-generation stents (FGSs; single-layer) in CAS. Methods: We performed a systematic review and meta-analysis of clinical studies with FGSs and SGS (PRISMA methodology, 3302 records). Endpoints were 30-day death, stroke, myocardial infarction (DSM), and 12-month ipsilateral stroke (IS) and restenosis (ISR). A random-effect model was applied. Results: Data of 68,422 patients from 112 eligible studies (68.2% men, 44.9% symptomatic) were meta-analyzed. Thirty-day DSM was 1.30% vs. 4.11% (p < 0.01, data for SGS vs. FGS). Among SGS, both Casper/Roadsaver and CGuard reduced 30-day DSM (by 2.78 and 3.03 absolute percent, p = 0.02 and p < 0.001), whereas the Gore stent was neutral. SGSs significantly improved outcomes compared with closed-cell FGS (30-day stroke 0.6% vs. 2.32%, p = 0.014; DSM 1.3% vs. 3.15%, p < 0.01). At 12 months, in relation to FGS, Casper/Roadsaver reduced IS (−3.25%, p < 0.05) but increased ISR (+3.19%, p = 0.04), CGuard showed a reduction in both IS and ISR (−3.13%, −3.63%; p = 0.01, p < 0.01), whereas the Gore stent was neutral. Conclusions: Pooled SGS use was associated with improved short- and long-term clinical results of CAS. Individual SGS types, however, differed significantly in their outcomes, indicating a lack of a “mesh stent” class effect. Findings from this meta-analysis may provide clinically relevant information in anticipation of large-scale randomized trials.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3