Author:
Khodja Abdellah,Paul Raphael,Fischer Andreas,Hoffmann Karl Heinz
Abstract
Vuilleumier refrigerators provide cooling power by utilizing a heat source at temperatures above the ambient. This is particularly helpful in situations where waste heat is available and other power sources are limited. Vuilleumier refrigerators come in different technical configurations; here we analyze the thermodynamic performance of a configuration utilizing two displacer pistons with integrated regenerators. More specifically, we optimize the cooling power by optimizing the piston movement for a range of operation speeds. The optimization is based on the AS motion class for cyclic dynamics and uses an endoreversible model for the refrigerator. Our focus is on the influence of the regeneration extent present, and we find performance gains of about 17% for high regeneration extent and of about 28% for lower regeneration extent.
Funder
German Federal Ministry of Education and Research
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献