An UPLC–ESI–MS/MS Bioanalytical Methodology for the Quantification of Gilteritinib in Human Liver Microsomes: Application to In Vitro and In Silico Metabolic Stability Estimation

Author:

Attwa Mohamed W.1ORCID,AlRabiah Haitham1,Alsibaee Aishah M.1ORCID,Abdelhameed Ali S.1ORCID,Kadi Adnan A.1ORCID

Affiliation:

1. Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia

Abstract

Gilteritinib (Xospata®) is a tyrosine kinase inhibitor (TKI) that works by inhibiting numerous receptor tyrosine kinases, involving AXL and FMS-like tyrosine kinase 3 (FLT3). Gilteritinib (GTB) was approved (28 November 2018) by the USFDA for the treatment of refractory or relapsed (R/R) acute myeloid leukemia (AML) with a FLT3 mutation. In the current study, a fast, highly sensitive, and specific ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) analytical methodology was created for GTB determination in human liver microsomes (HLMs) utilizing an electrospray ionization (ESI) source. The developed methodology (UPLC–ESI–MS/MS) was utilized in the assessment of GTB metabolic stability. The UPLC–ESI–MS/MS methodology was validated following the rules of the FDA that include selectivity, linearity, accuracy, precision, matrix effect, stability, and extraction recovery. The generated data of the optimized validation parameters of the current UPLC–ESI–MS/MS methodology were acceptable as reported in the FDA guidelines. GTB parent ions were generated in the ESI source (positive mode) and GTB daughter ions (two) were quantified in the mass analyzer utilizing multiple reaction monitoring (MRM) modes. The plotted GTB calibration curve showed a wide range of linearity from 1 ng/mL to 3000 ng/mL in HLMs matrix (y = 1.7298x + 3.62941 and r2 = 0.9949). The intraday and interday precision and accuracy outcomes of the current UPLC–ESI–MS/MS methodology were 0.35–11.39% and 0.27–4.32%, respectively. GTB and encorafenib (EFB) (internal standard; IS) were resoluted utilizing a reversed stationary phase (ZORBAX Eclipse plus C18 column; 1.8 μm PS, 2.1 mm ID, and 50 mm L) at 22 ± 2 °C. The calculated lower limit of quantification (LLOQ) was 0.94 ng/mL, revealing the UPLC–ESI–MS/MS methodology sensitivity. The two metabolic stability factors including in vitro half-life (t1/2) and intrinsic clearance (Clint) of GTB were 14.32 min and 56.64 mL/min/kg, respectively, predicting the moderate extraction ratio and good bioavailability of GTB. The current UPLC–ESI–MS/MS methodology is fast, sensitive and exhibits a wider range of linearity (1 to 3000 ng/mL) compared to other reported methods and is considered the first validated methodology for the determination of GTB metabolic stability.

Funder

Deputyship for Research & Innovation, “Ministry of Education” in Saudi Arabia

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3