Optimization of Chromatographic Conditions with QbD for Method Development and Validation of Bosutinib by HPLC: Applications in Dosage Forms and Rat Plasma Analysis

Author:

Najmi Asim1ORCID,Rehman Zia ur1,Alhazmi Hassan Ahmed12,Albratty Mohammed Mofarreh1,Majrashi Nasser Hassan3,Hakami Khalid Mohammed3,Najmi Naif Ali3,Mobarki Ammar Abdullah3

Affiliation:

1. Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Jazan University, P.O. Box 114, Jazan 45142, Saudi Arabia

2. Substance of Abuse and Research Toxicology Center, Faculty of Pharmacy, Jazan University, P.O. Box 114, Jazan 45142, Saudi Arabia

3. Faculty of Pharmacy, Jazan University, P.O. Box 114, Jazan 45142, Saudi Arabia

Abstract

Aim: Bosutinib (BST) is an anti-cancer medicine that is used to treat a variety of different types of cancer. Using the HPLC method of analysis and the Quality by Design (QbD) strategy, the study aimed to precisely quantify the drug in tablet form and in rat plasma. Methodology: For the developed method’s validation, the chromatographic settings were fine-tuned by making use of the Box–Behnken Design (BBD). In the BBD, two dependent variables and three independent variables were selected. Isocratically, samples were eluted, having eluent phase composition of ammonium acetate (CH3COONH4) buffer pH 3.0 and acetonitrile (CH3CN) (60:40% v/v), in Raptor C-18 column at temperature 25 ∘C with a flow rate of 1 mL/min for 5 min. The wavelength of detection was set at 260 nm. In this study, encorafenib (ENC) was employed as an internal standard. Result: A sharp and resolved peak of BST and ENC at a retention time of 1.92 min and 4.01 min, respectively, was observed by the developed method. The limits of quantification and detection of the newly established method were found to be 1.503 μg/mL−1 and 0.496 μg/mL−1. The calibration curve’s observed linearity range was between 2 and 20 μg/mL−1, with an r2 of 0.999. The developed and optimized method was verified in compliance with the ICH guidelines. The results of all validation parameters were within the acceptable range, for example, % RSD of system suitability (0.63–4.46), % RSD of linear regression (1.659), interday and intraday precision % RSD value (1.723–1.892), and (1.762–1.923), respectively, and accuracy (1.476–1.982). Conclusion: The quantity of BST in tablet dosage form and in rat plasma samples was determined using a simple, quick, and robust method that was devised and validated.

Funder

Deanship for Research and Innovation, Ministry of Education, Saudi Arabia

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3