Effects of Thermoforming on the Mechanical, Optical, Chemical, and Morphological Properties of PET-G: In Vitro Study

Author:

Staderini Edoardo12ORCID,Chiusolo Giuseppe1ORCID,Guglielmi Federica12ORCID,Papi Massimiliano34ORCID,Perini Giordano34ORCID,Tepedino Michele5ORCID,Gallenzi Patrizia12

Affiliation:

1. School of Dentistry, Dean: Prof. Massimo Cordaro, Catholic University of the Sacred Heart, IRCCS “A. Gemelli” University Polyclinic Foundation, Largo Agostino Gemelli 8, 00168 Rome, Italy

2. Postgraduate School of Orthodontics–Director: Prof. Massimo Cordaro, Catholic University of the Sacred Heart, Largo Agostino Gemelli 8, 00168 Rome, Italy

3. Department of Neurosciences, Catholic University of the Sacred Heart, Largo Francesco Vito 1, 00168 Rome, Italy

4. IRCCS “A. Gemelli” University Polyclinic Foundation, Largo Agostino Gemelli 8, 00168 Rome, Italy

5. Department of Biotechnological and Applied Clinical Sciences, University of L’Aquila, Piazza Santa Margherita 2, 67100 L’Aquila, Italy

Abstract

The effectiveness of clear aligners in correcting malocclusions is closely linked to the properties of the materials used to make them. The polymers used in the manufacture of clear aligners have well-established properties. However, the process of manufacturing clear aligners, known as thermoforming, involves thermal and mechanical shocks that may alter these properties. The objective of this study was to evaluate the effects of thermoforming on the mechanical, optical, chemical, and morphological properties of sixty PET-G specimens. The study compared the thickness, weight, absorbance, chemical structure, surface roughness, elastic modulus, yield strength, and breaking load of thirty thermoformed specimens with thirty non-thermoformed specimens. The study introduces a new approach by using standardized samples to analyze both chemical and physical properties. The results showed statistically significant differences in thickness (−15%), weight (−11%), and surface roughness (+1233% in roughness average; +1129% in RMS roughness) of the material. Additionally, a correlation was found between reduction in thickness and increase in opalescence. There was no significant change in the functionality of the aligners after thermoforming, as no significant mechanical changes were found. However, the increase in surface roughness may lead to plaque and fluid accumulation and worsen the fit of the aligners.

Funder

Università Cattolica del Sacro Cuore

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3