Development of Simultaneous Drug Concentration Measurement Method Using an Automated Pretreatment Liquid Chromatography/Tandem Mass Spectrometry System for Therapeutic Drug Monitoring

Author:

Sato Yu1ORCID,Kondo Hiroki1,Sato Yuji1,Abe Ai1,Kikuchi Masafumi12ORCID,Sato Toshihiro1ORCID,Kumondai Masaki1ORCID,Yoshikawa Kohei3ORCID,Hayakawa Yoshihiro3,Maekawa Masamitsu1ORCID,Mano Nariyasu1

Affiliation:

1. Department of Pharmaceutical Sciences, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan

2. Graduate School of Pharmaceutical Sciences, Tohoku University, 6-3 Aoba, Aramaki, Aoba-ku, Sendai 980-8578, Japan

3. Shimadzu Corporation, 1 Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan

Abstract

Therapeutic drug monitoring (TDM) is a personalized treatment approach that involves optimizing drug dosages based on patient-specific factors, such as drug plasma concentrations, therapeutic efficacy, or adverse reactions. The plasma concentration of drugs is determined using liquid chromatography/tandem mass spectrometry (LC-MS/MS) or various immunoassays. Compared with immunoassays, LC-MS/MS requires more pretreatment time as the number of samples increases. Recently, fully automated pretreatment LC-MS/MS systems have been developed to automatically perform whole-sample pretreatment for LC-MS/MS analysis. In this study, we developed a method for simultaneous concentration determination of five analytes (clozapine, mycophenolic acid, sunitinib, N-desethylsunitinib, and voriconazole) using LC-MS/MS for clinical TDM using a fully automated LC-MS/MS pretreatment system. In the developed method, the intra- and inter-assay relative error (RE) values ranged between −14.8% and 11.3%; the intra- and inter-assay coefficient of variation (CV) values were <8.8% and <10.5%, respectively. The analytes showed good stability, with RE values ranging between −13.6% and 10.9% and CV values <8.9%. Furthermore, the plasma concentrations in clinical samples using this method and the conventional manual pretreatment method showed similar results. Therefore, the method developed in this study could be considered a useful pretreatment method for routine TDM in patients.

Funder

Shimadzu Corporation

Publisher

MDPI AG

Reference31 articles.

1. Tuzimski, T., and Petruczynik, A. (2020). Review of chromatographic methods coupled with modern detection techniques applied in the therapeutic drugs monitoring (TDM). Molecules, 25.

2. Overview of therapeutic drug monitoring;Kang;Korean J. Intern. Med.,2009

3. Review of therapeutic drug monitoring of anticancer drugs part two--targeted therapies;Widmer;Eur. J. Cancer,2014

4. In vivo antitumor activity of SU11248, a novel tyrosine kinase inhibitor targeting vascular endothelial growth factor and platelet-derived growth factor receptors: Determination of a pharmacokinetic/pharmacodynamic relationship;Mendel;Clin. Cancer Res.,2003

5. Safety, pharmacokinetic, and antitumor activity of SU11248, a novel oral multitarget tyrosine kinase inhibitor, in patients with cancer;Faivre;J. Clin. Oncol.,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3