The Use of an Inspiration-Synchronized Vibrating Mesh Nebulizer for Prolonged Inhalative Iloprost Administration in Mechanically Ventilated Patients—An In Vitro Model

Author:

Otto Matthias1,Kropp Yannik1,Jäger Evelyn2,Neumaier Michael2,Thiel Manfred1,Quintel Michael34,Tsagogiorgas Charalambos15ORCID

Affiliation:

1. Department of Anaesthesiology and Critical Care Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Theodor-Kutzer-Ufer 1–3, 68165 Mannheim, Germany

2. Institute for Clinical Chemistry, Medical Faculty Mannheim of the University of Heidelberg, Theodor-Kutzer-Ufer 1–3, 68167 Mannheim, Germany

3. Department of Anaesthesiology, Emergency and Intensive Care Medicine, University of Göttingen, Robert-Koch-Str. 40, 37075 Göttingen, Germany

4. Department of Anaesthesiology, DONAUISAR Klinikum Deggendorf, Perlasberger Str. 41, 94469 Deggendorf, Germany

5. Department of Anaesthesiology and Critical Care Medicine, St. Elisabethen Hospital Frankfurt, Ginnheimer Straße 3, 60487 Frankfurt am Main, Germany

Abstract

Mechanically ventilated patients suffering from acute respiratory distress syndrome (ARDS) frequently receive aerosolized iloprost. Because of prostacyclin’s short half-life, prolonged inhalative administration might improve its clinical efficacy. But, this is technically challenging. A solution might be the use of inspiration-synchronized vibrating mesh nebulizers (VMNsyn), which achieve high drug deposition rates while showing prolonged nebulization times. However, there are no data comparing prolonged to bolus iloprost nebulization using a continuous vibrating mesh nebulizer (VMNcont) and investigating the effects of different ventilation modes on inspiration-synchronized nebulization. Therefore, in an in vitro model of mechanically ventilated adults, a VMNsyn and a VMNcont were compared in volume-controlled (VC-CMV) and pressure-controlled continuous mandatory ventilation (PC-CMV) regarding iloprost deposition rate and nebulization time. During VC-CMV, the deposition rate of the VMNsyn was comparable to the rate obtained with the VMNcont, but 10.9% lower during PC-CMV. The aerosol output of the VMNsyn during both ventilation modes was significantly lower compared to the VMNcont, leading to a 7.5 times longer nebulization time during VC-CMV and only to a 4.2 times longer nebulization time during PC-CMV. Inspiration-synchronized nebulization during VC-CMV mode therefore seems to be the most suitable for prolonged inhalative iloprost administration in mechanically ventilated patients.

Publisher

MDPI AG

Subject

Pharmaceutical Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3