Direct Temperature Measurements of Cardiac Stent during MRI Examinations

Author:

Acri Giuseppe1ORCID,Campanella Francesco2,Vermiglio Giuseppe3,Anfuso Carmelo4,Testagrossa Barbara1ORCID,Cavallaro Daniela4,Urzì Domenica4,Sanzo Antonio5,D’Avanzo Maria Antonietta2,Hartwig Valentina6ORCID

Affiliation:

1. Dipartimento di Scienze Biomediche, Odontoiatriche e Delle Immagini Morfologiche e Funzionali, Università Degli Studi di Messina, c/o A.O.U. Policlinico “G. Martino” Via Consolare Valeria, 98125 Messina, Italy

2. INAIL, Sezione di Supporto Tecnico al SSN in Materia di Radiazioni dell’INAIL, 00144 Rome, Italy

3. Medical Physicist (Freelance), 98122 Messina, Italy

4. IRCCS Centro Neurolesi Bonino-Pulejo, 98124 Messina, Italy

5. Fondazione IRCCS San Matteo, Arrhythmia and Electrophysiology Unit, 27100 Pavia, Italy

6. CNR, Institute of Clinical Physiology, 56124 Pisa, Italy

Abstract

Nowadays, Magnetic Resonance Imaging (MRI) is considered the gold standard for imaging the brain, spinal cord, musculoskeletal system, head and neck, and complex congenital heart malformations; consequentially, the number of MRI scans in patients with implantable electronic devices has simultaneously increased. During the entire length of the MRI exam, patients are exposed to electromagnetic fields with different characteristics (static, low frequency, radiofrequency fields), which are related to different risks. The scarce available literature about MRI-induced heating on cardiac stents suggests that excessive temperature rise occurs only in unfavorable cases. Ideally, RF safety assessment could be performed during the anamnestic process, but this simulation process’s results are too slow to be performed before patient MRI examination. In this context, we developed a dedicated measurement set-up by focusing our target on the measurement of the heating of a cardiac stent during an MRI examination. Results for the temperature rise trend along the entire stent length during a clinical MRI protocol are shown together with the local Specific Absorption Rate (SAR) values and cumulative equivalent minutes at 43 °C (CEM43°C), in order to ensure the safety of patients with MR-conditional devices, also with a view to not inappropriately preclude their access to MRI scans. The obtained results show that the maximum temperature rise (4.12 °C) is within the limit of 5 °C stated in the stent manual for 15 min of continued scanning with the specific conditions. The maximum temperature rise was in correspondence with the stent tips and calculated SAR confirms the fact that two hotspots are present near the tips of the stent. Finally, the calculated CEM43°C remained well below the proposed threshold for muscle tissue.

Funder

BRiC INAIL 2022

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3