Treatment of Soft Tissue Defects after Minimally Invasive Plate Osteosynthesis in Fractures of the Distal Tibia: Clinical Results after Reverse Sural Artery Flap

Author:

Lee Jun Young1,Lee Hyo Jun1,Yang Sung Hoon1,Ryu Je Hong1,Kim Hyoung Tae1,Lee Byung Ho2,Kim Sung Hwan3,Kim Ho Sung3,Lee Young Koo3

Affiliation:

1. Department of Orthopaedic Surgery, College of Medicine, Chosun University, 365 Pilmundae-ro, Dong-gu, Gwangju 61453, Republic of Korea

2. Department of Orthopaedic Surgery, Daejung Hospital, 180 Daein-ro, Dong-gu, Gwangju 61473, Republic of Korea

3. Department of Orthopaedic Surgery, Soonchunhyang University Hospital Bucheon, 170 Jomaru-ro, Wonmi-gu, Bucheon-si 14584, Republic of Korea

Abstract

Introduction: Distal tibial fractures make up approximately 3% to 10% of all tibial fractures or about 1% of lower extremity fractures. MIPO is an appropriate procedure and method to achieve stable metal plate fixation and osseointegration by minimizing soft tissue damage and vascular integrity at the fracture site. MIPO to the medial tibia during distal tibial fractures induces skin irritation due to the thickness of the metal plate, which causes discomfort and pain on the medial side of the distal leg, and if severe, complications such as infection and skin defect may occur. The reverse sural flap is a well-researched approach for covering defects in the lower third of the leg, ankle, and foot. Materials and Methods: Among 151 patients with distal tibia fractures who underwent minimally invasive metal plate fixation, soft tissue was injured due to postoperative complications. We treated 13 cases with necrosis and exposed metal plates by retrograde nasogastric artery flap surgery. For these patients, we collected obligatory patient records, radiological data, and wound photographs of the treatment results and complications of reconstructive surgery. Results: In all the cases, flap survival was confirmed at the final outpatient follow-up. The exposed area of the metal plate was well coated, and there was no plate failure due to complete necrosis. Three out of four women complained of aesthetic dissatisfaction because the volume of the tunnel through which the skin mirror passed and the skin plate itself were thick. In two cases, defatting was performed to reduce the thickness of the plate while removing the metal plate. Conclusions: Metal plate exposure after distal tibial fractures have been treated with minimally invasive metal plate fusion and can be successfully treated with retrograde nasogastric artery flaps, and several surgical techniques are used during flap surgery.

Funder

Chosun University

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. LncRNA MAGI2-AS3 promotes fracture healing through downregulation of miR-223-3p;Journal of Orthopaedic Surgery and Research;2024-06-22

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3