Comparison of the Incidence of Nd:YAG Laser Capsulotomy Based on the Type of Intraocular Lens

Author:

Lee Yuri1,Kim Jae Suk1,Kim Bum Gi1,Hwang Je Hyung1,Kang Min Ji1,Lee Jee Hye1

Affiliation:

1. Department of Ophthalmology, Sanggye Paik Hospital, Inje University College of Medicine, Seoul 01757, Republic of Korea

Abstract

Background and Objectives: Posterior capsular opacification (PCO) is the most common long-term complication of successful cataract surgery and can cause visual impairment. We aimed to investigate the effects of intraocular lens (IOL) characteristics on PCO by comparing the incidence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy for different types of intraocular lenses. Materials and Methods: A retrospective analysis was performed on 2866 eyes that underwent cataract surgery between January 2010 and December 2017, with at least 5 years of follow-up. The IOLs used for surgery were the hydrophobic lenses SN60WF (Alcon, Fort Worth, TX, USA), ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA), and MX60 (Bausch & Lomb, Rochester, NY, USA), and the hydrophilic lens MI60 (Bausch & Lomb, Rochester, NY, USA). We analyzed the incidence of Nd:YAG laser capsulotomy according to the type of IOL used. Results: The incidence of Nd:YAG laser capsulotomy was significantly higher with MI60 lenses (31.70%, 175/552 eyes) compared to SN60WF (7.90%, 113/1431 eyes), ZCB00 (10.06%, 64/636 eyes), and MX60 (10.57%, 13/123 eyes; p < 0.001) lenses. The incidence of Nd:YAG laser capsulotomy was significantly lower with the hydrophobic IOLs (8.68%, 190/2190 eyes) than with the hydrophilic IOL (31.70%, 175/552 eyes; p < 0.001). Over time, the rate of increase in the cumulative number of Nd:YAG laser capsulotomy cases was the highest with MI60. The cumulative rate of Nd:YAG laser capsulotomy during the first 3 years was 4.90% with SN60WF (70/1431 eyes), 6.76% with ZCB00 (43/636 eyes), 8.94% with MX60 (11/123 eyes), and 26.10% with MI60 (144/552 eyes) lenses. Conclusions: The incidence of PCO is influenced by the material of the IOLs. The hydrophilic IOL was associated with a higher rate of Nd:YAG laser capsulotomy than the hydrophobic IOLs, with a shorter time to Nd:YAG laser capsulotomy.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3