An MRI-Based Patient-Specific Computational Framework for the Calculation of Range of Motion of Total Hip Replacements

Author:

Kebbach MaeruanORCID,Schulze Christian,Meyenburg Christian,Kluess Daniel,Sungu Mevluet,Hartmann Albrecht,Günther Klaus-Peter,Bader Rainer

Abstract

The calculation of range of motion (ROM) is a key factor during preoperative planning of total hip replacements (THR), to reduce the risk of impingement and dislocation of the artificial hip joint. To support the preoperative assessment of THR, a magnetic resonance imaging (MRI)-based computational framework was generated; this enabled the estimation of patient-specific ROM and type of impingement (bone-to-bone, implant-to-bone, and implant-to-implant) postoperatively, using a three-dimensional computer-aided design (CAD) to visualize typical clinical joint movements. Hence, patient-specific CAD models from 19 patients were generated from MRI scans and a conventional total hip system (Bicontact® hip stem and Plasmacup® SC acetabular cup with a ceramic-on-ceramic bearing) was implanted virtually. As a verification of the framework, the ROM was compared between preoperatively planned and the postoperatively reconstructed situations; this was derived based on postoperative radiographs (n = 6 patients) during different clinically relevant movements. The data analysis revealed there was no significant difference between preoperatively planned and postoperatively reconstructed ROM (∆ROM) of maximum flexion (∆ROM = 0°, p = 0.854) and internal rotation (∆ROM = 1.8°, p = 0.917). Contrarily, minor differences were observed for the ROM during maximum external rotation (∆ROM = 9°, p = 0.046). Impingement, of all three types, was in good agreement with the preoperatively planned and postoperatively reconstructed scenarios during all movements. The calculated ROM reached physiological levels during flexion and internal rotation movement; however, it exceeded physiological levels during external rotation. Patients, where implant-to-implant impingement was detected, reached higher ROMs than patients with bone-to-bone impingement. The proposed framework provides the capability to predict postoperative ROM of THRs.

Funder

Aesculap AG Research and Development

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference81 articles.

1. Impingement and Dislocation in Total HIP Arthroplasty: Mechanisms and Consequences;Brown;Iowa Orthop. J.,2014

2. Krankenhaus-Report 2019;Klauber,2019

3. Health at a Glance 2017: OECD Indicators,2017

4. Prevalence of Total Hip and Knee Replacement in the United States

5. Impact of the Economic Downturn on Total Joint Replacement Demand in the United States