Clinical Comparison of the Glomerular Filtration Rate Calculated from Different Renal Depths and Formulae

Author:

Hsu Wen-Ling,Chang Shu-Min,Chang Chin-ChuanORCID

Abstract

A camera-based method using Technetium-99m diethylenetriaminepentaacetic acid (Tc-99m DTPA) is commonly used to calculate glomerular filtration rate (GFR), especially, as it can easily calculate split renal function. Renal depth is the main factor affecting the measurement of GFR accuracy. This study aimed to compare the difference of renal depths between three formulae and a CT scan, and, additionally, to calculate the GFRs by four methods. We retrospectively reviewed the medical records of patients receiving a renal dynamic scan. All patients underwent a laboratory test within one month, and a computed tomography (CT) scan within two months, before or after the renal dynamic scan. The GFRs were calculated by employing a renal dynamic scan using renal depth measured in three formulae (Tonnesen’s, Itoh K’s, and Taylor’s), and a CT scan. The renal depths measured by the above four methods were compared, and the GFRs were compared to the modified estimated GFR (eGFR). Fifty-one patients were enrolled in the study. The mean modified eGFR was 60.5 ± 42.7 mL/min. The mean GFRs calculated by three formulae and CT were 45.3 ± 23.3, 54.7 ± 27.5, 56.5 ± 26.3, and 63.7 ± 30.0, respectively. All of them correlated well with the modified eGFR (r = 0.87, 0.87, 0.87, and 0.84, respectively). The Bland–Altman plot revealed good consistency between the calculated GFR by Tonnesen’s and the modified eGFR. The renal depths measured using the three formulae were smaller than those measured using the CT scan, and the right renal depth was always larger than the left. In patients with modified eGFR > 60 mL/min, the GFR calculated by CT was the closest to the modified eGFR. The Renal depth measured by CT scan is deeper than that using formula, and it influences the GFR calculated by Gate’s method. The GFR calculated by CT is more closely related to modified eGFR when modified eGFR > 60 mL/min.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3