Abstract

Since the introduction of robot-assisted laparoscopic surgery, efforts have been made to incorporate force sensing technologies to monitor critical components and to provide force feedback. The advanced laparoscopic robotic system (AdLap RS) is a robotic platform that aims to make robot technology more sustainable through the use of the fully reusable shaft-actuated tip-articulating (SATA) instruments. The SATA instrument driver features electronics and sensors exposed to the sterile environment, which complicate the sterilisation process. The aim of this study was to develop and validate smart sensing in stepper motors using the back electromotive force in a newly developed Smart SATA Driver (SSD), eliminating the need for sensors in the sterile environment. Methods: The stepper drivers were equipped with TMC2209 ICs featuring StallGuard technology to measure back EMF. The tip was actuated up until a set StallGuard threshold value was reached, at which the resulting tip force was measured. This cycle was repeated ten times for a range of threshold levels. A regression analysis with a power series model was used to determine the quality of the fit. Results: The SSD is capable of exerting tip forces between 2.4 and 8.2 N. The back EMF force test demonstrated a strong correlation between obtained StallGuard values and measured tip forces. The regression analysis showed an R-squared of 0.95 and a root Mean squared error of 0.4 N. Discussion: The back EMF force test shows promise for force feedback, but its accuracy limits real-time use due to back EMF fluctuations. Future improvements in motor stability and refining the back EMF model are needed to enable real-time feedback. Conclusion: The strong correlation during the back EMF force test shows its potential as a low-budget method for detecting motor stalls and estimating tool–tissue forces without the need for sensors in laparoscopic instruments.

Funder

NWO

Publisher

MDPI AG

Reference27 articles.

1. Minimally invasive gastrointestinal surgery: From past to the future;Rudiman;Ann. Med. Surg.,2021

2. Robotic surgery techniques to improve traditional laparoscopy;Williamson;JSLS J. Soc. Laparosc. Robot. Surg.,2022

3. Robotic-assisted surgery for rectal cancer: Current state and future perspective;Matsuyama;Ann. Gastroenterol. Surg.,2018

4. Robotic-assisted surgery in gynecologic oncology;Sinno;Fertil. Steril.,2014

5. Review of emerging surgical robotic technology;Peters;Surg. Endosc.,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3