Accuracy of Multimodality Fetal Imaging (US, MRI, and CT) for Congenital Musculoskeletal Anomalies

Author:

Bisht Roy U.1ORCID,Belthur Mohan V.23ORCID,Singleton Ian M.1,Goncalves Luis F.456ORCID

Affiliation:

1. University of Arizona College of Medicine—Phoenix, 475 N. 5th St., Phoenix, AZ 85004, USA

2. Department of Child Health & Orthopedics, University of Arizona College of Medicine—Phoenix, 1919 E. Thomas Rd., Phoenix, AZ 85004, USA

3. Department of Surgery, Medical School, Creighton University, Omaha, NE 68178, USA

4. Department of Radiology, Phoenix Children’s Hospital, 1919 E. Thomas Rd., Phoenix, AZ 85016, USA

5. Child Health and Radiology, University of Arizona College of Medicine—Phoenix, 475 N. 5th St., Phoenix, AZ 85004, USA

6. Radiology, Mayo Clinic, 5777 E. Mayo Blvd., Phoenix, AZ 85054, USA

Abstract

Background: Ultrasonography (US) is the first-line diagnostic tool used to assess fetal musculoskeletal (MSK) anomalies. Associated anomalies in other organ systems may benefit from evaluation via Magnetic Resonance Imaging (MRI). In this study, we compared the diagnostic accuracy of US and MRI to diagnose fetal MSK (primary objective) and non-MSK anomalies (secondary objective). We describe additional findings by low-dose computerized tomography (CT) in two cases incompletely characterized via US and MRI. Materials and Methods: This was an IRB-approved retrospective study of consecutive patients with suspected fetal MSK anomalies examined between December 2015 and June 2020. We compared individual MSK and non-MSK anomalies identified via US, MRI, and CT with postnatal outcomes. Sensitivity and specificity for US and MRI were calculated and compared. Results: A total of 31 patients with 112 MSK and 43 non-MSK anomalies were included. The sensitivity of MRI and US for MSK anomalies was not significantly different (76.6% vs. 61.3%, p = 0.3). Low-dose CT identified eight additional skeletal anomalies. MRI diagnosed a higher number of non-MSK anomalies compared to US (81.4% vs. 37.2%, p < 0.05). Conclusions: Fetal MRI and US have comparable sensitivity for MSK anomalies. In selected cases, low-dose CT may provide additional information. Fetal MRI detected a larger number of non-MSK anomalies in other organ systems compared to US. Multimodality imaging combining all the information provided by MRI, US, and CT, if necessary, ultimately achieved a sensitivity of 89.2% (95% CI: 83.4% to 95.0%) for the diagnosis of musculoskeletal anomalies and 81.4% for additional anomalies in other organs and systems.

Publisher

MDPI AG

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3