Affiliation:
1. Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, 30625 Hannover, Germany
2. Medtronic GmbH, 40670 Meerbusch, Germany
Abstract
In patients with unexplained syncope, implantable loop recorders (ILR) are used to detect arrhythmias as a cause of syncope. This study aimed to assess the diagnostic yield and clinical implications arising from ILR implantation in patients with syncope in Germany. Secondary longitudinal data were obtained from a large German research database including anonymized data from nationwide statutory health insurances, representative for the German population. Patients ≥ 18 years with a diagnosis of syncope and ILR implantation between 2017 and 2018 were analyzed, and cardiac diagnoses and therapies during a follow-up period of two years assessed. Of 2,403,301 continuously insured persons in 2017–2018, 1360 (0.1%) received an ILR and 675 patients (45.6% female) were included. During follow-up, arrhythmias were diagnosed in 65.0%. The following antiarrhythmic therapies were established: pacemaker and defibrillator implantations in 20% and 1.5%, respectively, ablation therapy in 3.0%, and antiarrhythmic drug therapy in 4.7%. Aside from the diagnoses typically associated with syncope, atrial fibrillation or flutter was diagnosed in 37.0%, and anticoagulation therapy was initiated in 21.5%. There was a high diagnostic yield of arrhythmias following ILR implantation, leading to a relevant number of syncope-specific treatment. Arrhythmias not necessarily related to syncope were also diagnosed, leading to a high rate of anticoagulation therapy.