Design and Biomechanical Properties of Symmetrical Lumbar Fusion Cage Based on Lightweight Titanium Alloy Flexible Microporous Metal Rubber

Author:

Xiao Juan12,Zhu Tianqi13,Li Linlin3,Shen Liangliang14,Ren Zhiying3,Xu Jian14

Affiliation:

1. Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China

2. University of Chinese Academy of Sciences, Beijing 100049, China

3. School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou 350116, China

4. State Key Laboratory of Fine Chemicals, Liaoning High Performance Polymer Engineering Research Center, School of Chemical Engineering, Dalian University of Technology, Dalian 116024, China

Abstract

In recent years, the incidence rate of lumbar diseases has been progressively increasing. The conventional lumbar fusion cages used in existing lumbar interbody fusion surgery are not able to take into account the multiple characteristics of cushioning, vibration reduction, support, cell adhesion, and bone tissue growth. Therefore, in this work, based on the CT data of a lumbar intervertebral disc plain scan, a combined symmetric lumbar fusion cage structure was innovatively designed. The core was made of lightweight TC4 medical titanium alloy flexible microporous metal rubber (LTA-FMP MR), and the outer frame was made of cobalt–chromium–molybdenum alloy. Its comprehensive biomechanical performance was comprehensively evaluated through finite element simulation, static and dynamic mechanics, and impact resistance tests. The three-dimensional model of the L3/L4 lumbar segment was established by reverse engineering, and a Mises stress analysis was conducted on the lumbar fusion cage by importing it into Ansys to understand its structural advantages compared to the traditional lumbar fusion cage. Through static experiments, the influence of the internal nucleus of a symmetrical lumbar fusion cage with different material parameters on its static performance was explored. At the same time, to further explore the superior characteristics of this symmetrical structure in complex human environments, a biomechanical test platform was established to analyze its biomechanical performance under sinusoidal excitation of different amplitudes and frequencies, as well as impact loads of different amplitudes and pulse widths. The results show that under different amplitudes and frequencies, the lumbar fusion cage with a symmetrical structure has a small loss factor, a high impact isolation coefficient, and a maximum energy consumption of 422.8 N·mm, with a maximum kinetic energy attenuation rate of 0.43. Compared to existing traditional lumbar fusion cages in clinical practice, it not only has sufficient stiffness, but also has good vibration damping, support, and impact resistance performance, and has a lower probability of postoperative settlement, which has broad application prospects.

Funder

National Safety Academic Fund of China-NSAF

National Natural Science Foundation of China

Key Technologies Innovation and Industrialization Projects in Fujian Province

Publisher

MDPI AG

Subject

Physics and Astronomy (miscellaneous),General Mathematics,Chemistry (miscellaneous),Computer Science (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3