Comparison of Root Parallelism in Extraction Cases Treated with Clear Aligners vs. Fixed Appliances

Author:

Tao Tianjin,Liang Hengyan,Yan Xinyu,Fan Qi,Jiang Qingsong,Jian Fan,Long Hu,Lai Wenli

Abstract

In the process of orthodontic treatment, root parallelism is related to the relapse of extraction spaces, black triangles, and periodontal health. However, there are few studies on root parallelism in extraction cases with different types of appliances. The objective was to compare the root parallelism in extraction cases treated with clear aligners vs. those treated with fixed appliances by measuring the differences per extraction site and to access the root-movement control capacity of both orthodontic appliances. A retrospective study was conducted on cases in which the first premolars were extracted, treated by clear aligner appliance (“Invisalign” system, 28 patients) or fixed appliance (30 patients). The angulations of the tooth axis (canines, the second premolars, the first molars, and the second molars) were measured to analyze and compare the difference in root parallelism between the two orthodontic appliances. The percentage of root parallelism between the canine and second premolar in both groups had no significant difference. However, judging from the average angle difference value, the fixed appliance might have a greater range in root angulation adjustment than the aligner. In the angulation categories, the aligner mainly showed root apical divergence, while the fixed appliance mainly showed root apical convergence. The dental crown of the molars was mainly non-tipping in both groups, but it could be observed that the dental crown of the maxillary molars had a tendency toward mesial inclination. In conclusion, the same root parallelism and root inclination were obtained in tooth extraction cases whether treated by clear aligners or fixed appliances. This study provides clinicians with more information on the performance of clear aligners and fixed appliances.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3