Forward Light Scattering of First to Third Generation Vitreous Body Replacement Hydrogels after Surgical Application Compared to Conventional Silicone Oils and Vitreous Body

Author:

Hammer Maximilian12ORCID,Herth Jonathan23,Muuss Marcel2,Schickhardt Sonja1,Scheuerle Alexander2,Khoramnia Ramin2ORCID,Łabuz Grzegorz12,Uhl Philipp3,Auffarth Gerd Uwe12ORCID

Affiliation:

1. David J Apple Laboratory for Vision Research, 69120 Heidelberg, Germany

2. Department of Ophthalmology, University Clinic Heidelberg, 69120 Heidelberg, Germany

3. Institute for Pharmacy and Molecular Biotechnology, 69120 Heidelberg, Germany

Abstract

To treat certain vitreoretinal diseases, the vitreous body, a hydrogel composed of mostly collagen and hyaluronic acid, must be removed. After vitrectomy surgery, the vitreous cavity is filled with an endotamponade. Previously, pre-clinical hydrogel-based vitreous body substitutes either made from uncrosslinked monomers (1st generation), preformed crosslinked polymers (2nd generation), or in situ gelating polymers (3rd generation) have been developed. Forward light scattering is a measure of Stray light induced by optical media, when increased, causing visual disturbance and glare. During pinhole surgery, the hydrogels are injected into the vitreous cavity through a small 23G-cannula. The aim of this study was to assess if and to what extent forward light scattering is induced by vitreous body replacement hydrogels and if Stray light differs between different generations of vitreous body hydrogel replacements due to the different gelation mechanisms and fragmentation during injection. A modified C-Quant setup was used to objectively determine forward light scattering. In this study, we found that the 1st and 3rd generation vitreous body replacements show very low stray light levels even after injection (2.8 +/− 0.4 deg2/sr and 0.2 +/− 0.2 deg2/sr, respectively) as gel fragmentation and generation of interfaces is circumvented. The 2nd generation preformed hydrogels showed a permanent increase in stray light after injection that will most likely lead to symptoms such as glare when used in patients (11.9 +/− 0.9 deg2/sr). Stray light of the 2nd generation hydrogels was 3- and 2-fold increased compared to juvenile and aged vitreous bodies, respectively. In conclusion, this significant downside in the forward light scattering of the 2nd generation hydrogels should be kept in mind when developing vitreous body replacement strategies, as any source of stray light should be minimized in patients with retinal comorbidities.

Funder

Ernst und Berta Grimmke Foundation

Publisher

MDPI AG

Subject

Polymers and Plastics,Organic Chemistry,Biomaterials,Bioengineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3