Validity and Reliability of the Orthelligent Pro Sensor for Measuring Single-Leg Vertical Jump Height in Healthy Athletic Adults

Author:

Pasquale Caterina1,Baschung Pfister Pierrette2ORCID,Kuhn Manuel34ORCID,Stöggl Thomas56

Affiliation:

1. Department of Physiotherapy and Occupational Therapy, University Hospital Zurich, 8091 Zurich, Switzerland

2. Directorate of Research and Education, Physiotherapy Occupational Therapy Research Center, University Hospital Zurich, 8091 Zurich, Switzerland

3. Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland

4. Department of Pulmonology, University Hospital Zurich, 8091 Zurich, Switzerland

5. Department of Sport and Exercise Science, University of Salzburg, 5020 Salzburg, Austria

6. Red Bull Athlete Performance Center, 5303 Salzburg, Austria

Abstract

The Orthelligent Pro sensor is a practicable, portable measuring instrument. This study assessed the validity and reliability of this sensor in measuring single-leg countermovement jumps. Fifty healthy athletic adults participated in two measurement sessions a week apart in time. They performed single-leg countermovement jumps on the force plate while wearing the Orthelligent Pro sensor on their lower leg. During the first measurement session, Tester 1 invited the participants to make three single-leg countermovement jumps; subsequently, Tester 2 did the same. For assessing the sensor’s intratester reliability, Tester 1 again invited the participants to make three single-leg countermovement jumps during the second measurement session. The sensor’s validity was assessed by using the force plate results as the gold standard. To determinate the agreement between two measurements, Bland–Altman plots were created. The intertester reliability (ICC = 0.99; 0.97) and intratester reliability (ICC = 0.96; 0.82) were both excellent. The validity calculated (i) on the basis of the mean value of three jumps and (ii) on the basis of the maximum value of three jumps was very high, but it showed a systematic error. Taking this error into account, physiotherapists can use the Orthelligent Pro sensor as a valid and reliable instrument for measuring the jump height of countermovement jumps.

Funder

Swiss Association of Physiotherpy

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3