The Reliability of Three-Dimensional Landmark-Based Craniomaxillofacial and Airway Cephalometric Analysis

Author:

Yao Kan123ORCID,Xie Yilun4,Xia Liang123,Wei Silong123,Yu Wenwen123,Shen Guofang123

Affiliation:

1. Department of Oral and Cranio-Maxillofacial Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China

2. College of Stomatology, Shanghai Jiao Tong University, Shanghai 200011, China

3. National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200011, China

4. Department of Stomatology, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China

Abstract

Cephalometric analysis is a standard diagnostic tool in orthodontics and craniofacial surgery. Today, as conventional 2D cephalometry is limited and susceptible to analysis bias, a more reliable and user-friendly three-dimensional system that includes hard tissue, soft tissue, and airways is demanded in clinical practice. We launched our study to develop such a system based on CT data and landmarks. This study aims to determine whether the data labeled through our process is highly qualified and whether the soft tissue and airway data derived from CT scans are reliable. We enrolled 15 patients (seven males, eight females, 26.47 ± 3.44 years old) diagnosed with either non-syndromic dento–maxillofacial deformities or OSDB in this study to evaluate the intra- and inter-examiner reliability of our system. A total of 126 landmarks were adopted and divided into five sets by region: 28 cranial points, 25 mandibular points, 20 teeth points, 48 soft tissue points, and 6 airway points. All the landmarks were labeled by two experienced clinical practitioners, either of whom had labeled all the data twice at least one month apart. Furthermore, 78 parameters of three sets were calculated in this study: 42 skeletal parameters (23 angular and 19 linear), 27 soft tissue parameters (9 angular and 18 linear), and 9 upper airway parameters (2 linear, 4 areal, and 3 voluminal). Intraclass correlation coefficient (ICC) was used to evaluate the inter-examiner and intra-examiner reliability of landmark coordinate values and measurement parameters. The overwhelming majority of the landmarks showed excellent intra- and inter-examiner reliability. For skeletal parameters, angular parameters indicated better reliability, while linear parameters performed better for soft tissue parameters. The intra- and inter-examiner ICCs of airway parameters referred to excellent reliability. In summary, the data labeled through our process are qualified, and the soft tissue and airway data derived from CT scans are reliable. Landmarks that are not commonly used in clinical practice may require additional attention while labeling as they are prone to poor reliability. Measurement parameters with values close to 0 tend to have low reliability. We believe this three-dimensional cephalometric system would reach clinical application.

Funder

Interdisciplinary Program of Shanghai Jiao Tong University

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference80 articles.

1. Die Bedeutung der Röntgenfern- und Abstandsaufnahme Für die Diagnostik der Kieferanomalien;Hofrath;Fortschritte Orthod. Theor. Prax.,1931

2. A new X-ray technique and its application to orthodontia;Broadbent;Angle Orthod.,1931

3. A New Method of 3-D Cephalometry Part I: The Anatomic Cartesian 3-D Reference System;Swennen;J. Craniofacial Surg.,2006

4. New Clinical Protocol to Evaluate Craniomaxillofacial Deformity and Plan Surgical Correction;Xia;J. Oral Maxillofac. Surg.,2009

5. Taub, P.J., Patel, P.K., Buchman, S.R., and Cohen, M.N. (2015). Ferraro’s Fundamentals of Maxillofacial Surgery, Springer.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3