Albuminuria Is Affected by Urinary Tract Infection: A Comparison between Biochemical Quantitative Method and Automatic Urine Chemistry Analyzer UC-3500

Author:

Chou Yi-Ju1ORCID,Yang Chun-Chun2,Chang Shang-Jen3,Yang Stephen Shei-Dei14ORCID

Affiliation:

1. Division of Urology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, New Taipei 23142, Taiwan

2. Department of General Laboratory, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, New Taipei 23142, Taiwan

3. Department of Urology, National Taiwan University Hospital, Taipei 10002, Taiwan

4. School of Medicine, Tzu Chi University, Hualien 97004, Taiwan

Abstract

The automated urine reagent strip test is a cost-effective tool for detecting albuminuria in patients. However, prior research has not investigated how urinary tract infections (UTIs) affect the test’s accuracy. Therefore, this study aims to assess the impact of UTIs on albuminuria diagnosis using both the biochemical quantitative method and the test strip method of the Fully Automatic Urine Chemistry Analyzer, UC-3500 (Sysmex, Kobe, Japan). From March to December 2019, we prospectively collected midstream urine from adult female UTI patients before and after one week of cephalexin treatment. The urine samples were subjected to culture, routine urinalysis, and albuminuria diagnosis using the biochemical quantitative method and UC-3500. Albuminuria was defined as a urine albumin to creatinine ratio (UACR) ≥ 30 mg/g in the biochemical quantitative method. The results were compared between the two methods. Among fifty-four female patients (average age: 50.5 ± 4.4 years) with UTIs, 24 (44.44%) had transient albuminuria. The quantitative UACR significantly decreased after one week of antibiotic treatment (median: 53 mg/g to 9 mg/g; median difference: −0.54, p < 0.0001). UC-3500 exhibited a higher false positive rate for diagnosing albuminuria during UTIs (42%) compared to after treatment (19%). Its agreement with the biochemical quantitative method was moderate during UTI (κ = 0.49, 95% confidence interval [CI]: 0.24–0.73) and good after treatment (κ = 0.65, 95% CI: 0.45–0.86). UC-3500’s accuracy in diagnosing albuminuria is influenced by UTIs, leading to either transient albuminuria or a false positive reaction of the test strip. UTI should be excluded or treated before its application in albuminuria screening.

Funder

Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference29 articles.

1. Kidney Disease: Improving Global Outcomes (KDIGO) CKD Work Group. KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease;Levin;Kidney Int. Suppl.,2013

2. Urinary albumin strip assay as a screening test to replace quantitative technology in certain conditions;Salinas;Chem. Lab. Med.,2018

3. Diagnostic accuracy of a reagent strip for assessing urinary albumin excretion in the general population;Graziani;Nephrol. Dial. Transplant.,2009

4. A sensitive quantitative test strip based point-of-care albuminuria screening assay;Decavele;Chem. Lab. Med.,2012

5. Comparison of Urine Albumin-to-Creatinine Ratio (ACR) Between ACR Strip Test and Quantitative Test in Prediabetes and Diabetes;Nah;Ann. Lab. Med.,2017

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3