Assessment of the Periodontal Cementum Ablation Depth during Root Planing by an Er:YAG Laser at Different Energy Densities: An Ex Vivo Study

Author:

Nahas Paul1,Houeis Saad2,Chamboredon Remi2,Heysselaer Daniel2,Zeinoun Toni3,Nammour Samir2ORCID

Affiliation:

1. Department of Restorative and Esthetic Dentistry, Faculty of Dental Medicine, Lebanese University, Hadath campus, Beirut 1003, Lebanon

2. Department of Dental Science, Faculty of Medicine, University of Liege, 4000 Liege, Belgium

3. Department of Oral and Maxillo-Facial Surgery, Dean of Faculty of Dental Medicine, Lebanese University, Beirut 1003, Lebanon

Abstract

Introduction: An important and non-adapted delivered energy of Er:YAG laser can eliminate the total thickness of root cementum during root planing. Conversely, the preservation of a partial layer of cementum covering the roots is vital for any periodontal ligament regeneration. Thus, the assessment of the cementum ablation depth produced by each energy density of Er:YAG laser is essential before considering its use for the periodontal planing and treatment of the cementum and root surfaces. Aim of the study: Assessment of the cementum ablation depth at different energy densities of the Er:YAG laser is the aim of this study. Materials and methods: A total of 48 human caries free molars were collected and used in this study. Areas to be irradiated were delimited by two longitudinal grooves (0.5 mm depth). Roots were divided randomly into four groups (4 × n = 12). An Er:YAG laser (2.94 µm) was used with a side-firing tip (R600T) with a 600 µm diameter and a frequency of 20 Hz combined with a cooling system of air 6 mL/min and water 4 mL/min. We used a super short pulse mode (SSP: pulse duration: 50 μs). We used a single irradiation passage backward from apex to cervical parts at 1 mm/s with a slight contact and at an angle of 15° to 30° between the tip and the root surface. Different energies were selected: 30 mJ, 40 mJ, 50 mJ, and 60 mJ. Results: Microscopic observations showed that the average of the ablation depth increased with the increase of the delivered energy from 30 mJ to 60 mJ. Mean values of the ablation depths were respectively as follows: 43.75 ± 4.89 µm for the energy of 30 mJ, 50.05 ± 3.72 µm for 40 mJ, 65.56 ± 10.35 µm for 50 mJ, and 74.80 ± 15.23 µm for 60 mJ. A statistically significant difference existed between the ablation depth of all groups. Conclusion: Based on our results, the depth of cementum debridement is related to the level of the delivered energy. The lowest energy levels (30 mJ and 40 mJ) can ablate the root cementum surface for a variable depth from 43.75 ± 4.89 μm to 50.05 ± 3.72 μm.

Publisher

MDPI AG

Subject

General Dentistry

Reference47 articles.

1. Shklar, G., and Carranza, F. (2019). Newman and Carranza’s Clinical Periodontology, Elsevier. [13th ed.].

2. Periodontal diseases;Kinane;Nat. Rev. Dis. Prim.,2017

3. Glickman, I. (1953). Clinical Periodontology, WB Saunders.

4. Newmann, M., Takei, H., Klokkevold, P., and Carranza, F. (2012). Carranza’s Clinical Periodontology, Elsevier Saunders. [11th ed.].

5. Scaling and root planing vs. conservative surgery in the treatment of chronic periodontitis;Deas;Periodontol. 2000,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3