Assessing Isometric Quadriceps and Hamstring Strength in Young Men and Women: Between-Session Reliability and Concurrent Validity

Author:

Mellemkjær Frederik H.1,Madeleine Pascal1ORCID,Nørgaard Jens E.23,Jørgensen Martin G.23,Kristiansen Mathias1

Affiliation:

1. ExerciseTech, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9260 Gistrup, Denmark

2. Department of Geriatric Medicine, Aalborg University Hospital, 9000 Aalborg, Denmark

3. Department of Clinical Medicine, Faculty of Medicine, Aalborg University, 9260 Gistrup, Denmark

Abstract

This study assessed the between-session reliability of the FysioMeter H-station when measuring isometric quadriceps and hamstrings strength and H/Q (hamstring/quadriceps) ratio, and the concurrent validity when compared to an isokinetic dynamometer (ID). Sixteen young males and three females (25.6 ± 1.7 years old) performed maximum quadriceps and hamstring contractions using the H-station and the Humac NORM ID over two sessions. Between-session reliability was evaluated by comparing scores from the first and the second session. Concurrent validity was assessed by comparing scores from the H-station with the Humac NORM ID. The H-station showed excellent relative reliability for the quadriceps, hamstring, and the H/Q ratio with ICC2.1 ranging from 0.89 to 0.91. The relative reliability of the Humac NORM was good to moderate for the quadriceps, hamstring, and the H/Q ratio with ICC2.1 ranging from 0.89 to 0.91. Acceptable absolute reliability of the H-station was found across quadriceps, hamstring, and H/Q measures (coefficient of variance (CV) = 7.2 to 9.3%, limit of agreement (LOA) = 20.0 to 24.3%). The validity of the H-station was large for hamstring strength (r = 0.79) and moderate for quadriceps strength (r = 0.69) and H/Q ratio (r = 0.39) compared to the Humac NORM ID. Bland–Altman plots showed LOAs ranging from 37.9 to 59.5%. The results indicate that the H-station can be used to make reliable assessments of relative changes in maximum isometric quadriceps and hamstring strength.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference32 articles.

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3